In this study, bioactive glass-ferrite (Fe₃O₄) hybrid coatings were deposited on commercially pure titanium using an electric-field-assisted electrophoretic deposition (EPD) technique, and their microstructural and functional properties were quantitatively evaluated. Bioactive glass co-deposited with 5 wt.% Fe₃O₄ particles at a constant applied voltage of 25 V, while the deposition time was systematically varied between 6- and 24-min. Microstructural observations revealed that short deposition times (6-12 min) resulted in discontinuous and non-uniform coatings, whereas prolonged deposition (18-24 min) produced dense, continuous, and well-adhered layers. Wettability measurements showed a pronounced enhancement in surface hydrophilicity, with water contact angles decreasing from 57.6 ± 1.22° for the bare substrate to 35.4 ± 1.35° and 18.9 ± 1.18° for coatings deposited for 12 and 24 min, respectively. Electrochemical tests in phosphate-buffered saline at 37 °C demonstrated that increasing deposition time improved the barrier performance of the coatings, as evidenced by a reduction in corrosion current density from 8.16 × 10⁻⁷ A/cm² at 18 min to 2.95 × 10⁻⁷ A/cm² at 24 min, alongside an increase in charge transfer resistance from 1.35 × 10⁴ to 4.58 × 10⁴ Ω·cm². Although the uncoated titanium exhibited the highest intrinsic corrosion resistance due to its stable passive oxide layer, the optimized hybrid coating deposited at 25 V for 24 min offered the best compromise between enhanced surface roughness, superior wettability, and improved electrochemical performance among the coated samples.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Surface Treatment and Residual Stress · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Jiang M, Li Y, Zhang H. Corrosion resistance and plasma surface treatment on titanium and titanium alloys: a review. Coatings. 2025;15:1180.10.3390/coatings15101180 ↗
2. Hrir H, Boudouma A, Layachi OA, Harrati A, Hsissou R, Khoumri E. An in-depth review of corrosion pathways in titanium dental and orthopedic implants and their biological interactions. Biomed Mater Devices. 2025;4:446–66.10.1007/s44174-025-00300-w ↗
3. Zhang L, Zhang H. Ti-based metallic glass composites containing β-Ti dendrites. Prog Mater Sci. 2025;152:101472.10.1016/j.pmatsci.2025.101472 ↗
4. Ahn TK, Lee DH, Kim TS, Jang GC, Choi S, Oh JB et al. Modification of titanium implant and titanium dioxide for bone tissue engineering. Adv Exp Med Biol. 2018;1077:355-68.10.1007/978-981-13-0947-2_19 ↗
5. Ogawa T, Hirota M, Shibata R, Matsuura T, Komatsu K, Saruta J, et al. The 3D theory of osseointegration: material, topography, and time as interdependent determinants of bone–implant integration. Int J Implant Dent. 2025;11:49.10.1186/s40729-025-00639-1 ↗
6. Lu X, Zhao Y, Peng X, Lu C, Wu Z, Xu H, et al. Comprehensive overview of interface strategies in implant osseointegration. Adv Funct Mater. 2025;35:2418849.10.1002/adfm.202418849 ↗
7. Hao X, Jiang B, Wu J, Xiang D, Xiong Z, Li C, et al. Nanomaterials for bone metastasis. J Control Release. 2024;373:640–51.10.1016/j.jconrel.2024.07.067 ↗
8. Nadian N, Nourouzi S, Jamshidi Aval H. Innovative plasma spray coating of HA-Ti-MgO composite on Ti6Al4V alloy for enhanced performance. J Mater Sci Mater Med. 2025;36:63.10.1007/s10856-025-06920-4 ↗
9. Guo D, Jin R, Shi B, Jia X, Wang S, Xu B. Interaction of nanostructured Lu2Si2O7/Lu2SiO5 double-ceramic layer environmental barrier coatings with CMAS. Surf Coat Technol. 2025;502:131994.10.1016/j.surfcoat.2025.131994 ↗
10. Wu Y, Wan K, Lu J, Yuan C, Cui Y, Duan R, et al. Research progress on surface modification of titanium implants. Coatings. 2025;15:229.10.3390/coatings15020229 ↗
11. Pei H, Wang S, Zhang H, Yu H, Shi X, Yang Y, et al. Oxidation-creep damage assessment of Ni-based single-crystal superalloy and coated system. J Mater Sci Technol. 2026;260:13–29.10.1016/j.jmst.2025.09.059 ↗
12. Du J, Huang J, Dong C, Cui S, Liu W, Zhang X, et al. Influence of an Nb interlayer on the oxidation behavior of a Cr coating deposited on Inconel 718 alloy substrate. J Mater Res Technol. 2025;39:9283–97.10.1016/j.jmrt.2025.11.197 ↗
13. Rodríguez-Rego JM, Macías-García A, Mendoza-Cerezo L, Díaz-Parralejo A, Marco-Romero AC. New electrical method for obtaining graphic information on the evaluation of the uniformity of ZrO2-3 mol% and Y2O3 coatings deposited by electrophoresis. Application in the protection and finishing of dental parts. J Mater Sci Mater Med. 2025;36:34.10.1007/s10856-025-06876-5 ↗
14. He J, Cheng X, Zhang S, Tao Y, Shi H. Fabrication and characterization of an anti-corrosion/infection VAN@PLGA/HA/CMCS composite coating on magnesium alloy. J Mater Sci Mater Med. 2025;36:96.10.1007/s10856-025-06956-6 ↗
15. Genchev M, Nagels C, Schmal H, Kubosch EJ, Lanzino MC, Killinger A, et al. Effect of thin porous ceramic coatings on implant stability: a comparative study of GB14 and β-TCP with and without Cu. J Mater Sci Mater Med. 2026;37:40.10.1007/s10856-026-07013-6 ↗
16. Nayak SK, Kumar A, Laha T. Fe-based metallic glass coatings by thermal spraying: a focused review on corrosion properties and related degradation mechanisms. Int Mater Rev. 2023;68:404–85.10.1080/09506608.2022.2084670 ↗
17. Sohani Z, Aval HJ, Rabiee SM. Bioactive glass and iron oxide nanoparticle composite coatings for Ti-6Al-4V implants: microstructure, corrosion behavior, bioactivity and cellular response. Appl Surf Sci Adv. 2025;27:100734.10.1016/j.apsadv.2025.100734 ↗
18. Tehrani MM, Chaboki P, Mohammadi R, Chinian S, Motallebzadeh S, Abosaoda MK, et al. An overview of types of antibacterial coatings and methods for creating them on orthodontic wires. J Mater Sci Mater Med. 2025;37:12.10.1007/s10856-025-06992-2 ↗
19. Sohani Z, Aval HJ, Rabiee SM. Exploring the morphology and bioactivity of bioglass-iron oxide coatings on Ti6Al4V implants via electrophoretic deposition. Surf Topography Metrol Prop. 2025;13:045003.10.1088/2051-672X/ae0b97 ↗
20. Sohani Z, Aval HJ, Rabiee SM. Analysis of the structure and characteristics of bioglass–iron oxide composite layers on Ti-6Al-4V alloy via electrophoretic deposition. Compos C Open Access. 2025;18:100639.10.1016/j.jcomc.2025.100639 ↗
21. Kumar S, Nasna P, Ghosh G. Recent advancement in biocompatible materials, hybrid bioactive coating, surface modification and post-processing techniques for the fabrication of biomedical implants: critical review and future prospects. Proc Inst Mech Eng Part C J Mech Eng Sci. 2025;239:3247–86.10.1177/09544062241307455 ↗
22. Wang Y, Zhai W, Li J, Liu H, Li C, Li J. Friction behavior of biodegradable electrospun polyester nanofibrous membranes. Tribology Int. 2023;188:108891.10.1016/j.triboint.2023.108891 ↗
23. Ma C, He H, Zhang H, Li Z, Wei L, Xia F. Impact of magnetic field direction on performance and structure of Ni-Co-SiC coatings fabricated via magnetic-field-induced electrodeposition. Coatings. 2024;14:672.10.3390/coatings14060672 ↗
24. Lin J, Kilani M, Baharfar M, Wang R, Mao G. Understanding the nanoscale phenomena of nucleation and crystal growth in electrodeposition. Nanoscale. 2024;16:19564–88.10.1039/D4NR02389G ↗
25. Kou W, Gou J, Gao J, Zhu J, Zhang D. Effect of cold metal transfer mode and arc oscillation on the microstructure and properties of additive-manufactured 2319 aluminum alloy. Mater Sci Technol. 2025;2046536373. https://doi.org/10.1177/02670836251383115.10.1177/02670836251383115 ↗
26. Hammami I, Fernandes Graça MP, Gavinho SR, Regadas JS, Jakka SK, Pádua AS, et al. Influence of zirconium dioxide (ZrO2) and magnetite (Fe3O4) additions on the structural, electrical, and biological properties of Bioglass® for metal implant coatings. Front Bioeng Biotechnol. 2025;13:1537856.10.3389/fbioe.2025.1537856 ↗
27. Liu Y, Shao L, Zhang S, Hu L, Wu Y, Liu C, et al. Effect of chemical composition and heat treatment on the microstructure and performance of Ag-based alloy wires. Mater Des. 2025;258:114728.10.1016/j.matdes.2025.114728 ↗
28. Maltoni P, Baričić M, Barucca G, Spadaro MC, Arbiol J, Yaacoub N, et al. Tunable particle-agglomeration and magnetic coupling in bi-magnetic nanocomposites. Phys Chem Chem Phys. 2023;25:27817–28.10.1039/D3CP03689H ↗
29. Ogawa T, Shibata R, Komatsu K, Matsuura T, Chao D, Park W, et al. Bridging the missing middle in osseointegration: meso-scale topography between macro design and microroughness. Int J Implant Dent. 2025;11:68.10.1186/s40729-025-00656-0 ↗
30. Beyrami H, Golshan M, Zardehi-Tabriz A, Salami-Kalajahi M. Smart coatings: fundamentals, preparation approaches, and applications. Adv Mater Technol. 2025;10:e00574.10.1002/admt.202500574 ↗
31. Zhang P, Yue X, Jiang X, Sun Y, Wang Y. Study on the influence of multi-energy field combined surface modification on the subsurface microstructure evolution of AA7075 aluminum alloy. Mater Charact. 2025;219:114644.10.1016/j.matchar.2024.114644 ↗
32. Thakur A, Kumar A, Kaya S, Marzouki R, Zhang F, Guo L. Recent advancements in surface modification, characterization and functionalization for enhancing the biocompatibility and corrosion resistance of biomedical implants. Coatings. 2022;12:1459.10.3390/coatings12101459 ↗
33. Chen S, Zhou Y, Zhang N, Chen Q, Peng P, Deng M. Microstructure regulation and tribological response mechanism of β-Si3N4-modified 304 stainless-steel coatings. J Mater Eng Perform. 2026;36:13–19.10.1007/s11665-025-12966-w ↗