Synthesis and characterization of plasma sprayed functional gradient bioceramic coating for medical implant applications
Source abstract
Abstract
Abstract The dissolution of plasma-sprayed hydroxyapatite (HA) coating in physiological media is complex and involves numerous factors. It is generally believed that the highly crystalline HA coatings are beneficial for long-term stability, whereas amorphous layers dissolve more quickly and promote early biointegration. In the present study, the functionally gradient coating (FGC) was formulated in three successive layers over Ti6Al4V alloy using an atmospheric plasma spray (APS) process. At the inner layer, the titania (TiO2) bond coat is applied to enhance adhesion strength. In the middle layer, crystalline hydroxyapatite (HA) coating was deposited to provide long-term stability. In contrast, the outer amorphous layer of as-sprayed HA coating was assumed to promote the early implant bonding with host bone. The crystallinity level of the middle HA layer was increased by post coating heat treatment at 700 C for 1 h. There is an improvement in microhardness value after heat treatment from 276.6 ± 91.2 HV to 316.3 ± 41.4 HV. The corresponding porosity and surface roughness values decreased from 15 to 11% and 5.81 ± 1.00 to 5.22 ± 0.84 μm, respectively. In addition, the post coating heat treatment of the middle layer minimized the plasma spray process defects, such as micro-cracks and voids. Furthermore, a corrosion study in the ringer solution shows that heat treatment effectively enhanced the corrosion resistance of the middle crystalline HA layer. Nevertheless, the TiO2 bond coat enhanced the adhesion strength of functional gradient coating from 21.70 MPa to 30.50 MPa. The findings of this study indicate that surface modification with functional gradient coating is a promising approach to improve the performance of the Ti6Al4V alloy for biomedical applications.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (68)
Show source-provided references
1. Design, development and Tribological characterization of Ti-6Al-4V/hydroxyapatite composite for Bio-implant applications10.1201/9780367816094 ↗
2. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
3. Incorporation of wollastonite bioactive ceramic with titanium for medical applications : an overview10.1016/j.msec.2018.12.056 ↗
4. Investigation of corrosion behavior and surface properties of plasma sprayed HA/Sr reinforced coatings on CoCr alloys10.1016/j.matchemphys.2020.123330 ↗
5. Wear behavior of plasma sprayed hydroxyapatite bioceramic coating in simulated body fluid10.1016/j.ceramint.2018.11.137 ↗
6. Calcium orthophosphate coatings on magnesium and its biodegradable alloys10.1016/j.actbio.2014.02.026 ↗
7. Influence of post coating heat treatment on microstructural, mechanical and electrochemical corrosion behaviour of vacuum plasma sprayed reinforced hydroxyapatite coatings10.1016/j.jmbbm.2018.05.030 ↗
8. Hiromoto · 2019
9. In vitro investigation of Nb e Ta alloy coating deposited on CoCr alloy for biomedical implants10.1016/j.surfcoat.2019.124932 ↗
10. Narushima · 2019
11. Matsushita · 2019
12. Composition, structure and mechanical properties of the titanium surface after induction heat treatment followed by modification with hydroxyapatite nanoparticles10.1016/j.ceramint.2016.03.213 ↗
13. Characterization and biocompatibility study of hydroxyapatite coating on the surface of titanium alloy10.1016/j.surfcoat.2019.07.067 ↗
14. Corrosion behaviour of plasma sprayed graphene nanoplatelets reinforced hydroxyapatite composite coatings in simulated body fluid
15. Composition, structure and mechanical properties of metal oxide coatings produced on titanium using plasma spraying and modified by micro-arc oxidation10.1016/j.ceramint.2018.04.056 ↗
16. Improvement in mechanical properties of plasma sprayed hydroxyapatite coatings by Al2O3 reinforcement10.1016/j.msec.2013.03.005 ↗
17. Acta Biomaterialia Mechanical and biological properties of ZnO , SiO 2 , and Ag 2 O doped plasma sprayed hydroxyapatite coating for orthopaedic and dental applications10.1016/j.actbio.2019.05.020 ↗
18. Assessing the biocompatibility of degradable metallic materials : state-of-the-art and focus on the potential of genetic regulation10.1016/j.actbio.2010.02.027 ↗
19. Effect of spark plasma sintering on the microstructure and in vitro behavior of plasma sprayed HA coatings10.1016/S0142-9612(03)00082-6 ↗
20. Characterization and corrosion resistance of plasma sprayed HA and HA–SiO2 coatings on Ti–6Al–4V10.1016/j.surfcoat.2013.04.036 ↗
21. Influence of composite powders' microstructure on the microstructure and properties of Al2O3-TiO2 coatings fabricated by plasma spraying10.1016/j.matdes.2014.09.078 ↗
22. Study of the crystal structure of hydroxyapatite in plasma coating10.1016/j.surfcoat.2019.05.037 ↗
23. Microstructural and in vitro characterization of 45S5 bioactive glass coatings deposited by solution precursor plasma spraying ( SPPS )10.1016/j.surfcoat.2018.12.057 ↗
24. Adhesion strength of plasma-sprayed hydroxyapatite coatings on laser gas-nitrided pure titanium10.1016/j.surfcoat.2009.03.034 ↗
25. Zhao · 2008 · vol. 202 · 3221
26. Characterization and mechanical behavior of reinforced hydroxyapatite coatings deposited by vacuum plasma spray on SS-316L alloy10.1016/j.jmbbm.2018.01.005 ↗
27. Effect of post-heat treatment on the microstructure of micro-plasma sprayed hydroxyapatite coatings10.1016/j.surfcoat.2019.03.056 ↗
28. Microstructural characterizations of plasma sprayed hydroxyapatite coatings10.1016/S0257-8972(02)00855-1 ↗
29. Plasma-sprayed hydroxylapatite coatings as biocompatible intermediaries between inorganic implant surfaces and living tissue10.1007/s11666-018-0737-8 ↗
30. Tissue reactions around a hydroxyapatite-coated hip prosthesis: case report of a retrieved specimen10.1016/S0883-5403(05)80190-1 ↗
31. Study on the influence of plasma spray processes and spray parameters on the structure and crystallinity of hydroxylapatite coatings10.1002/mawe.200600029 ↗
32. Phase, structural and microstructural investigations of plasma sprayed hydroxyapatite coatings10.1016/S0921-5093(03)00439-8 ↗
33. Substrate preheating and structural properties of power plasma sprayed hydroxyapatite coatings10.1016/j.ceramint.2015.08.125 ↗
34. Investigation of crystallinity, mechanical properties, fracture toughness and cell proliferation in plasma sprayed graphene nano platelets reinforced hydroxyapatite coating10.1088/2053-1591/ab6c23 ↗
35. Immersion behavior of plasma-sprayed modified hydroxyapatite coatings after heat treatment10.1016/S0257-8972(02)00745-4 ↗
36. Influence of processing parameters and heat treatment on phase composition and microstructure of plasma sprayed hydroxyapatite coatings10.1016/S1003-6326(10)60090-8 ↗
37. Post-deposition laser treatment of plasma sprayed titania-hydroxyapatite functionally graded coatings10.1016/j.jeurceramsoc.2009.05.053 ↗
38. In vivo evaluation of plasma sprayed hydroxyapatite coatings having different crystallinity10.1016/S0142-9612(03)00545-3 ↗
39. Microstructural self-healing effect of hydrothermal crystallization on bonding strength and failure mechanism of hydroxyapatite coatings10.1016/j.jeurceramsoc.2008.02.015 ↗
40. In vivo biological responses of plasma sprayed hydroxyapatite coatings with an electric polarized treatment in alkaline solution10.1016/j.msec.2009.07.002 ↗
41. Plasma sprayed hydroxyapatite coatings on titanium substrates Part 2: optimisation of coating properties10.1016/S0142-9612(98)00104-5 ↗
42. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti – 6Al – 4V composite coatings10.1016/j.biomaterials.2003.10.089 ↗
43. 9 A review of hydroxyapatite coatings manufactured by thermal spray10.1007/978-3-642-53980-0_9 ↗
44. Mechanical performances and microstructural characteristics of plasma-sprayed bio-functionally gradient HA – ZrO 2 – Ti coatings10.1016/j.surfcoat.2005.05.004 ↗
45. Residual stress evaluation within hydroxyapatite coatings of different micrometer thicknesses10.1016/j.surfcoat.2015.02.040 ↗
46. In vitro characterization of postheat-treated plasma-sprayed hydroxyapatite coatings10.1016/j.surfcoat.2004.09.025 ↗
47. Microstructural inhomogeneity in plasma-sprayed hydroxyapatite coatings and effect of post-heat treatment10.1016/j.apsusc.2005.04.021 ↗
48. Characterization of plasma sprayed hydroxyapatite/ZrO 2 graded coating10.1016/j.matdes.2009.02.002 ↗
49. Application of response surface methodology in the design of functionally graded plasma sprayed hydroxyapatite coatings Tanya10.1016/j.surfcoat.2017.01.113 ↗
50. Plasma spraying of functionally graded hydroxyapatite/Ti-6Al-4V coatings10.1016/S0257-8972(03)00238-X ↗
51. Characterization of functionally graded hydroxyapatite/titanium composite coatings plasma-sprayed on Ti alloys
52. Deposition and investigation of functionally graded calcium phosphate coatings on titanium10.1016/j.actbio.2009.05.013 ↗
53. Surface characterization of plasma sprayed pure and reinforced hydroxyapatite coating on Ti6Al4V alloy10.1016/j.surfcoat.2011.04.064 ↗
54. Studies on corrosion resistance and bio-activity of plasma spray deposited hydroxylapatite (HA) based TiO2 and ZrO2 dispersed composite coatings on titanium alloy ( Ti-6Al-4V ) and the same after post spray heat treatment10.1016/j.apsusc.2017.05.208 ↗
55. Mechanical and chemical properties of Baghdadite coatings manufactured by atmospheric plasma spraying10.1016/j.surfcoat.2019.124945 ↗
56. Factors influencing phase compositions and structure of plasma sprayed hydroxyapatite coatings during heat treatment10.1016/S0169-4332(02)01308-9 ↗
57. Structure, mechanical performance and electrochemical characterization of plasma sprayed SiO2/Ti-reinforced hydroxyapatite biomedical coatings10.1016/j.apsusc.2008.09.088 ↗
58. Changes in phases and crystallinity of plasma‐sprayed hydroxyapatite coatings under heat treatment: a quantitative study10.1002/jbm.820291204 ↗
59. Moulder · 1992
60. Characterization of chemical inhomogeneity in plasma-sprayed hydroxyapatite coatings10.1016/S0142-9612(03)00061-9 ↗
61. Materials Today : proceedings In-vitro performance of reinforced hydroxyapatite coatings deposited using vacuum plasma spray technique on Ti-6Al-4V
62. Effect of surface roughness of hydroxyapatite on human bone marrow cell adhesion, proliferation, differentiation and detachment strength10.1016/S0142-9612(00)00174-5 ↗
63. Titanium oxide nanotubes with controlled morphology for enhanced bone growth10.1016/j.msec.2005.08.014 ↗
64. Development of plasma-sprayed bioceramic coatings with bond coats based on titania and zirconia10.1016/S0142-9612(98)00067-2 ↗
65. Effects of TiO2 on microstructural , mechanical properties and in-vitro bioactivity of plasma sprayed yttria stabilised zirconia coatings for dental application10.1016/j.ceramint.2017.12.008 ↗
66. Mechanical and biological properties of graded porous tantalum coatings deposited on titanium alloy implants by vacuum plasma spraying10.1016/j.surfcoat.2019.05.003 ↗
67. In vitro corrosion behavior and cytocompatibility of pure Fe implanted with Ta10.1016/j.surfcoat.2017.01.051 ↗
68. Electrochemical study of the in vitro degradation of plasma-sprayed hydroxyapatite/bioactive glass composite coatings after heat treatment10.1016/j.electacta.2004.08.001 ↗