Abstract Reproducibility of the sensor response is one of the fundamental themes for obtaining marketable devices with a high degree of reliability. This parameter becomes decisive especially if the sensor signals are used to identify compound mixtures by means of recognition algorithms. In fact, to apply the same algorithm to different devices, sensors must be identical within a minimum error margin. This point became crucial for medical diagnostic tools, e.g., for cancer screening and monitoring. A set of three thermo-activated thick-film Zinc Oxide (ZnO) sensors, obtained from the same screen-printing deposition, have been tested in laboratory with diverse gases and two biological fecal samples. Fecal samples have been employed in the clinical validation protocol of a device for non-invasive colorectal cancer pre-screening, as emitters of oncologic volatile biomarkers. Sensors showed a good reproducibility degree, with an error lower than 10% of response value for all compounds, reaching 1%–2% for some gases.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Advanced Chemical Sensor Technologies · Electrical and Thermal Properties of Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Preventive screening of colorectal cancer with a device based on chemoresistive sensors
2. Use of gas sensors and FOBT for the early detection of colorectal cancer10.1016/j.snb.2018.01.225 ↗
3. Neoplasms and metastasis detection in human blood exhalations with a device composed by nanostructured sensors10.1016/j.snb.2018.05.102 ↗
4. Sol-gel materials for gas-sensing applications10.1016/0925-4005(93)01060-H ↗
5. Chemoresistive gas sensors for detection of colorectal cancer biomarkers10.3390/s141018982 ↗
6. Detection of colorectal cancer biomarkers in the presence of interfering gases10.1016/j.snb.2015.04.080 ↗
7. Landini · 2015
8. Zonta · 2019 · 301
9. ZnO and Au/ZnO thin films: room-temperature chemoresistive properties for gas sensing applications10.1016/j.snb.2016.07.134 ↗
10. Chemoresistive properties of photo-activated thin and thick ZnO films10.1016/j.snb.2015.06.048 ↗
11. Guidi · 2012 · 278
12. Bruker AXS. TOPAS 4−1 User Manual; Bruker AXS GmbH,Karlsruhe, Germany.
13. Cheary · J. Appl. Crystallogr. · 1992 · 25 · 10910.1107/S0021889891010804 ↗
14. Cheary · J. Res. Natl. Inst. Stand.Technol. · 2004 · 109 · 110.6028/jres.109.002 ↗
15. Kern · 2004
16. 2004
17. D. Balzar, In Microstructure Analysis from Diffraction.
18. 1999
19. Limited crystallite growth upon isothermal annealing of nanocrystalline anatase10.1021/acs.cgd.5b00068 ↗
20. Lopez · 2013 · 2013 · 7
21. ZnO gas sensors: a comparison between nanoparticles and nanotetrapods-based thick films10.1016/j.snb.2008.11.007 ↗
22. Fast response methane sensor using nanocrystalline zinc oxide thin films derived by sol–gel method10.1016/j.snb.2006.11.046 ↗
23. Design and development of ZnO based gas sensor for fruit ripening detection
24. CO and NO2 selective monitoring by ZnO-based sensors10.3390/nano3030357 ↗
25. How the chamber design can affect gas sensor responses
26. Patent · 2014
27. Patent · 2015