High-frequency gradient 1-3 piezoelectric composites and ultrasonic transducer for medical imaging
Source abstract
Abstract
High-frequency ultrasonic transducers are essential for high-resolution clinical diagnostics or industrial non-destructive testing. While 1-3 piezoelectric composites offer superior acoustic impedance matching and electromechanical coupling efficiency compared to traditional bulk ceramics, their high-frequency performance is often compromised by periodic lateral vibration modes. These parasitic resonances significantly degrade sensitivity, bandwidth, and imaging quality. To overcome this limitation without increasing manufacturing complexity, this study proposes a gradient-structure piezoelectric composite that uses a non-periodic distribution of piezoelectric pillars to physically disrupts the phase coherence of lateral standing waves. The structural parameters of the piezocomposite were optimized and validated using theoretical derivation and Finite Element Analysis (FEA). Compared to conventional designs, our fabricated high-frequency gradient composite transducer showed significantly improved –6 dB bandwidth (73%), electromechanical coupling coefficient (0.74), and pulse-echo sensitivity. Furthermore, the imaging experiments performed on phantom, tungsten wire and ex vivo tissues indicated that the gradient transducer achieves superior resolution and Contrast-to-Noise Ratio (CNR). These findings indicate that the gradient structure design provides a practical solution to current performance bottlenecks of high-frequency transducers, offering substantial theoretical significance and broad application potential in precision medical ultrasound imaging. • Novel gradient-structure 1-3 composites are proposed for high-frequency (≥20 MHz) transducers. • Aperiodic structure distribution suppresses lateral modes by disrupting phase coherence. • High-performance devices are fabricated without relying on ultra-fine kerf widths. • Achieved superior k eff (0.74) and –6 dB bandwidth (73%) compared to periodic structures. • Phantom and ex vivo tissue imaging results demonstrate enhanced resolution and contrast.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Ultrasound and Hyperthermia Applications · Ferroelectric and Piezoelectric Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. High frequency ultrasonic imaging10.1016/S0929-6441(09)60012-6 ↗
2. Piezoelectric single crystals for ultrasonic transducers in biomedical applications10.1016/j.pmatsci.2014.06.001 ↗
3. A 30-MHz piezo-composite ultrasound array for medical imaging applications10.1109/58.985706 ↗
4. A 30-MHz, 3-D Imaging, forward-looking miniature endoscope based on a 128-element relaxor array10.1109/TUFFC.2020.3027907 ↗
5. Micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular array10.1016/j.ultras.2011.11.001 ↗
6. Design and micromanufacturing technologies of focused piezoelectric ultrasound transducers for biomedical applications10.1088/2631-7990/ad62c6 ↗
7. Numerical Study of a miniaturized, 1–3 piezoelectric composite focused ultrasound transducer10.3390/app13010615 ↗
8. Synergistic anti-cancer therapy through ultrasound-induced piezocatalytic therapy and tumor treatment fields10.1002/advs.202511604 ↗
9. 60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging
10. Crosstalk optimization of 5 MHz linear array transducer based on PZT/epoxy piezoelectric composite10.1016/j.sna.2022.113500 ↗
11. Theoretical calculation model of emission performance for 1-3 piezoelectric composite transducer10.1080/00150193.2021.1951047 ↗
12. Research on high sensitivity integrated transmit and receive hydroacoustic transducer10.1088/1402-4896/ad0c16 ↗
13. Piezoelectric composites: State-of-the-art and future prospects10.1007/s11837-023-06202-w ↗
14. KNNS-BNZH Lead-free 1-3 piezoelectric composite for ultrasonic and photoacoustic imaging10.1109/TUFFC.2019.2914464 ↗
15. Wide-bandwidth immersion ultrasound transducer made of Mn:PIMNT single crystal/epoxy 1–3 composite10.1016/j.sna.2024.115196 ↗
16. PIN-PMN-PT single-crystal-based 1–3 piezoelectric composites for ultrasonic transducer applications10.1007/s11664-013-2627-7 ↗
17. Enhanced electromechanical properties of Eu-doped PIN-PMN-PT relaxor ferroelectric single crystal with high electric-optic properties10.1016/j.jmst.2025.03.036 ↗
18. The concept of a novel hybrid smart composite reinforced with radially aligned zigzag carbon nanotubes on piezoelectric fibers10.1088/0964-1726/19/3/035008 ↗
19. 1-3 ceramic/polymer composites for high-temperature transducer applications10.1002/pssa.201228787 ↗
20. Preparation and simulation of lead free NBBT/epoxy 1–3 piezoelectric composites for high frequency medical ultrasound10.1016/j.coco.2022.101399 ↗
21. Novel Piezo-active 2–1–2 composites with sets of large hydrostatic parameters10.1080/07315171.2023.2238175 ↗
22. Micromachining of high-quality PMN-PT/Epoxy 1-3 composite for high-frequency (>30 MHz) ultrasonic transducer applications10.1109/TUFFC.2023.3320652 ↗
23. Micromechanics-based predictions of effective properties of a 1-3 piezocomposite reinforced with hollow piezoelectric fibers10.1080/15376494.2018.1529842 ↗
24. Increasing performances of 1-3 piezocomposite ultrasonic transducer by alternating current poling method10.3390/mi13101715 ↗
25. Design of planar array transducers based on connected 1-3 piezoelectric composites10.3390/mi12111417 ↗
26. Design and properties analysis of novel modified 1-3 piezoelectric composite10.3390/ma14071749 ↗
27. Fabrication and high acoustic performance of high frequency needle ultrasound transducer with PMN-PT/Epoxy 1-3 piezoelectric composite prepared by dice and fill method10.1016/j.sna.2020.112528 ↗
28. Squared figures of merit and electromechanical coupling factors of a novel lead-free 1–3–0 composite for sensor and energy-harvesting applications10.1016/j.sna.2020.112473 ↗
29. Electromechanical coupling coefficient and acoustic impedance of 1-1-3 piezoelectric composites10.1016/j.ceramint.2017.02.148 ↗
30. Flexible 1-3 piezoelectric composites with soft embedded conductive interconnects for underwater acoustic transducers10.1021/acsaelm.3c00155 ↗
31. Homogenized electromechanical coefficients and effective parameters of 1–3 piezocomposites for ultrasound imaging transducers10.1016/j.physleta.2021.127492 ↗
32. Fabrication and performance of high-frequency composite transducers with triangular-pillar geometry10.1109/TUFFC.2009.1106 ↗
33. Design of low-loss 1-3 piezoelectric composites for high-power transducer applications10.1109/TUFFC.2012.2415 ↗
34. Design and fabrication of air-based 1-3 piezoelectric composite transducer for air-coupled ultrasonic applications
35. Design, preparation and electromechanical characteristics analysis of piezoelectric 1-3-type composites with sandwich polymer structures10.1016/j.sna.2024.115024 ↗
36. Tailoring the properties of composite piezoelectric materials for medical ultrasonic transducers
37. Theoretical study on the static performance of piezoelectric ceramic-polymer composites with 2-2 connectivity10.1109/58.212557 ↗
38. Broadband 1-3 piezoelectric composite transducer design using sierpinski gasket fractal geometry10.1109/TUFFC.2018.2874384 ↗
39. Design and fabrication of non-periodic 1-3 composite structure for ultrasonic transducer application10.1016/j.compstruct.2022.115249 ↗
40. Effect of filling material properties on 1-3 piezoelectric composite performance10.3390/mi15070812 ↗
41. Gradient piezoelectric composites for ultrasonic transducer design and imaging applications10.1016/j.jmat.2025.101049 ↗
42. 0.36BiScO3-0.64PbTiO3/Epoxy 1-3-2 high- temperature composite ultrasonic transducer for nondestructive testing applications10.1109/TUFFC.2024.3388552 ↗
43. 1-3-Type piezoelectric composites with three-layer cascade structure10.1016/j.compstruct.2023.117406 ↗
44. Interdigital pair bonding for high frequency (20–50 MHz) ultrasonic composite transducers10.1109/58.896143 ↗
45. Design and properties 1–3 multi-element piezoelectric composite with low crosstalk effects10.1016/j.ceramint.2017.08.047 ↗
46. Finite element method simulation, design, and fabrication of micromachined high-frequency piezoelectric composite with hexagonal pillars for intravascular ultrasound imaging10.1007/s10854-024-12605-5 ↗
47. Micromachined high frequency 1-3 piezocomposite transducer using picosecond laser10.1109/TUFFC.2021.3059942 ↗
48. Integration of impedance-gradient and oriented alignment structure in carbon fiber composites enabling thermal management and microwave absorption10.26599/NR.2025.94908025 ↗
49. A high-sensitivity, broadband (1A,1B)-3 single-crystal composite ultrasonic transducer10.1002/adfm.202417084 ↗