journal article·2008-01

Combined Microwave and Electron Beam Exposure Facilities for Medical Studies an Applications

Diana Martin, Sabin Cinca, Irina Margaritescu, Monica Neagu, Nicusor Iacob, Daniel Ighigeanu, Constantin Matei, Gabriela Craciun, Elena Manaila, Chirta Doru Aurel, Mihaela Moisescu

Publisher page

Abstract

The paper presents two radiation exposure facilities (REFs) which permit separate and simultaneous irradiation with microwaves (MW) of 2.45 GHz and electron beams (EB) of 6.23 MeV for malignant melanoma (MM) cell investigations, in vitro (MW+EB-REF-vitro) and in vivo (MW+EB-REF-vivo). The REFs are specifically designed for the following medical studies: 1) The effects of separate and combined (successive and simultaneous) MW and EB irradiation on the B16F10 mouse--MM cell cultures without/with drugs incubation, 2) The effects of separate and combined MW and EB irradiation on human blood components irradiated in samples of integral blood from healthy donors and from donors with MM; 3) The effects of separate and combined MW and EB whole body irradiation on the C57 BL/6 mice bearing MM without/with drugs administration. Several representative results obtained by experiments with REFs in vitro and in vivo are discussed. The most important conclusion of the experimental results is that low dose-total body MW+EB irradiation combined with drugs administration could present a valuable potential for an advanced study in malignant melanoma therapy.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microbial Inactivation Methods · Radiation Effects and Dosimetry · bioluminescence and chemiluminescence research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (5)

Show source-provided references
1. Green, I. (1991). “Hyperthermia in Conjunction with Cancer Chemeotherapy.”Health Technology Assessment, pp.2.
2. Olofsson, L. (2005). “Energy and Intensity Modulated Radiation Therapy with Electrons.”Print & Media,Umea, Sweden.
3. Persch C. and Schubert, H. (1995). “Characterization of household microwave ovens by their efficiency and quality parameter.”Proc. of 5thInternational Conference on Microwave and High Frequency Heating, England UK, pp.S31.1-S31.4
4. Smolko, E. E. and Lombardo, J. H. (2005). “Virus inactivation studies using ion beams, electron and gamma irradiation.”Nucl. Instr. andMeth. in Phys. Res. B, pp.249–253.10.1016/j.nimb.2005.04.055 ↗
5. Van de Loosdrecht, A., Beelen, R. H. J., Ossenkoppele, G. J., Broekhoven, M. G. and Langenhuijsen, A. C. (1994). “A tetrazolium-based colorimetric MTT assay to quantitate human monocyte mediated cytotoxicity against leukemic cells from cell lines and patients with acute myeloid leukemia”J. Immunol. Methods, 174(1–2), pp.311–320.10.1016/0022-1759(94)90034-5 ↗