Comparative study of the hydroxyapatite coatings prepared with/without substrate bias
Source abstract
Abstract
Abstract The aim of this paper is to prepare the hydroxyapatite by Ion Beam Assisted Deposition and to investigate in terms of its elemental and phase composition, roughness and in vitro corrosion resistance. The coatings were prepared with and without applying bias on substrate, in order to find the effect of bias on the chemical, structural, morphological and anti-corrosive properties. The biased coatings exhibited Ca/P ratio closer to the value of the stoichiometric HAP (1.67). The phase composition is not affected by the bias evolution. The adhesion of both coatings is still satisfactory for biomedical applications, irrespective of the bias. Hydroxyapatite deposited without bias presented the best corrosion resistance in SBF at 37 °C, probably due to its smooth surface and low porosity. Moreover, this coating proved to have the highest protection ability at the SBF corrosive attack.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Metal and Thin Film Mechanics · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. 2011
2. Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis - a review10.1016/j.actbio.2013.10.036 ↗
3. Hydroxyapatite nanoparticles: a review of preparation methodologies
4. A review of plasma-assisted methods for calcium phosphate-based coatings fabrication10.1016/j.surfcoat.2011.11.002 ↗
5. A review on calcium phosphate coatings produced using a sputtering process – an alternative to plasma spraying10.1016/j.biomaterials.2004.02.029 ↗
6. Shepherd · 2015
7. Hydroxyapatite and hydroxyapatite-based ceramics10.1023/A:1020585800572 ↗
8. Martinu · 2010
9. R.F. Bunshah, Vapor deposition technologies, in: Handb. Hard Coatings Depos. Technol. Prop. Appl., 2001, pp. 4–76. 〈http://books.google.com/books?id=daamnz8el2sC&pgis=1〉.
10. The influence of the deposition parameters on the properties of an rf-magnetron-deposited nanostructured calcium phosphate coating and a possible growth mechanism10.1016/j.surfcoat.2010.12.039 ↗
11. Influence of the crystallinity of a sputtered hydroxyapatite film on its osteocompatibility
12. Effect of the deposition temperature on corrosion resistance and biocompatibility of the hydroxyapatite coatings10.1016/j.apsusc.2015.05.059 ↗
13. Mechanical properties and fractal analysis of the surface texture of sputtered hydroxyapatite coatings10.1016/j.apsusc.2016.04.077 ↗
14. A study on microstructure and properties of calcium phosphate coatings processed using ion beam assisted deposition on heated substrates10.1016/j.surfcoat.2006.10.039 ↗
15. Modification of the structure and composition of Ca 10 (PO 4) 6 (OH) 2 ceramic coatings by changing the deposition conditions in O2 and Ar10.1088/1742-6596/514/1/012017 ↗
16. Formation of solution-derived hydroxyapatite coatings on titanium alloy in the presence of magnetron-sputtered alumina bond coats10.2174/1874120701509010075 ↗
17. Titanium carbide coatings deposited by reactive ion beam-assisted, electron beam-physical vapor deposition10.1016/S0257-8972(99)00644-1 ↗
18. Science and technology of high dielectric constant thin films and materials integration for application to high frequency devices10.1023/B:JECR.0000034006.59246.5e ↗
19. Influence of bias voltage on the microstructure and physical properties of magnetron sputtered Zr-Si-N nanocomposite thin films10.1016/j.surfcoat.2009.06.042 ↗
20. Effect of substrate bias voltage on the structure, electric and dielectric properties of TiO2 thin films by DC magnetron sputtering10.1016/j.apsusc.2011.10.047 ↗
21. Influence of substrate bias voltage on the properties of magnetron sputtered Cu2O films10.1016/j.physb.2005.08.041 ↗
22. Effects of substrate bias on structure and mechanical properties of (AlCrNbSiTiV)N coatings10.1088/0022-3727/42/11/115401 ↗
23. Effect of substrate bias on microstructure and properties of Ni-TiN nanocomposite thin films deposited by reactive magnetron co-sputtering10.1016/j.surfcoat.2014.04.032 ↗
24. Study of the mechanical behavior and corrosion resistance ofhydroxyapatite sol–gel thin coatings on 316 L stainless steel pre-coated with titania film10.1016/j.tsf.2015.09.037 ↗
25. Problems of atomic science and technology
26. Low pressure gas discharge in magnetically insulated diode
27. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
28. R.Z. LeGeros, Calcium Phosphates in Oral Biology and Medicine. 〈http://www.ncbi.nlm.nih.gov/pubmed/1870604〉.
29. The ultrastructure of the bone-Hydroxyapatite interface in vitro10.1002/jbm.820261008 ↗
30. In vitro dissolution of various calcium-phosphate coatings on Ti6Al4V
31. H.H. Soliman, roughness parameters10.1016/S0924-0136(02)00060-2 ↗
32. Comparative investigation on the adhesion of hydroxyapatite coating on Ti–6Al–4V implant: a review paper10.1016/j.ijadhadh.2013.09.030 ↗
33. The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation10.5114/aoms.2012.28545 ↗
34. Impedance study on the corrosion of PVD and CVD titanium nitride coatings
35. One- and two-dimensional polymer films of modified alkanethiol monolayers for preventing iron from corrosion10.1016/S0010-938X(98)00048-1 ↗
36. Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications10.1016/S0010-938X(03)00148-3 ↗
37. Corrosion behavior and biocompatibility of hydroxyapatite coating on H2SO4 passivated 316L SS for human body implant10.1007/s40195-012-0212-3 ↗
38. Effect of surface roughness on early stages of pitting corrosion of Type 301 stainless steel10.1016/S0010-938X(97)00072-3 ↗
39. Surface roughness and the metastable pitting of stainless steel in chloride solutions10.5006/1.3293603 ↗
40. Influence of roughness on surface instability of medical grade cobalt-chromium alloy (CoCrMo) during contact corrosion-fatigue10.1016/j.apsusc.2013.02.076 ↗
41. R. Walter, M.B. Kannan, Influence of surface roughness on the corrosion behaviour of magnesium alloy, 2011. 〈http://dx.doi.org/10.1016/j.matdes.2010.12.016〉.10.1016/j.matdes.2010.12.016 ↗
42. Metastable pitting corrosion of 304 stainless steel in 3.5% NaCl solution10.1016/j.corsci.2014.04.033 ↗
43. Effects of surface roughness of substrate on properties of Ti/TiN/Zr/ZrN multilayer coatings10.1016/S1003-6326(15)63623-8 ↗
44. Using scratch testing to measure the adhesion strength of calcium phosphate coatings applied to poly(carbonate urethane) substrates10.1016/j.jmbbm.2011.10.010 ↗