Use of cryogenic machining to improve the adhesion of sphene bioceramic coatings on titanium substrates for dental and orthopaedic applications
Source abstract
Abstract
Abstract Rods of commercially pure titanium were machined using standard oil-based emulsion and cryogenic cooling, and were then coated with sphene (CaTiSiO5) bioceramic by spray coating using an automatic airbrush. The sphene bioceramic was synthesized in-situ starting from a suspension of polysiloxane that used as SiO2 precursor, CaCO3 and TiO2 nanoparticles. The suspension was deposited on the machined substrates, which were heat treated up to 950 °C in order to promote the formation of sphene ceramic. The produced coated prototypes were characterized to evaluate the effect of the machining conditions on surface roughness and microstructure of the substrate, and thereby their effect on coating adhesion. Nanoindentation tests were employed to determine the hardness and elastic modulus of the coating through its thickness. Results showed that the reduced amount of defects on the surface of the cryo-machined substrates, contributed to increase the hardness, elastic modulus and adhesion strength of the coating-substrate interfaces compared to standard machined samples, therefore improving adhesion of the coating to the underlying substrate.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review10.1016/j.pmatsci.2008.06.004 ↗
2. Metal release from ceramic coatings for dental implants
3. Incorporation of titanium into calcium silicate improved their chemical stability and biological properties10.1002/jbm.a.31623 ↗
4. Novel sphene coatings on Ti–6Al–4V for orthopedic implants using sol–gel method10.1016/j.actbio.2007.11.005 ↗
5. Polymer-derived sphene biocoating on cp-Ti substrates for orthopedic and dental implants10.1016/j.surfcoat.2016.01.018 ↗
6. Bioactive sphene-based ceramic coatings on cpTi substrates for orthopedic and dental implants: an in vitro study10.3390/ma11112234 ↗
7. Machinability of titanium alloys (Ti6Al4V and Ti555.3)
8. Optimization of titanium alloy Ti6Al4V machining10.1016/S0924-0136(03)00457-6 ↗
9. Cryogenic processing of biomaterials for improved surface integrity and product sustainability10.1007/978-3-642-20183-7_26 ↗
10. Fretting corrosion behavior of additive manufactured and cryogenic-machined Ti6Al4V for biomedical applications
11. Surface integrity in dry and cryogenic machining of AZ31B Mg alloy with varying cutting edge radius tools10.1016/j.proeng.2011.11.113 ↗
12. The effects of cooling conditions on surface integrity in machining of Ti6Al4V alloy10.1007/s00170-013-5477-9 ↗
13. Analysis of tool wear in cryogenic machining of additive manufactured Ti6Al4V alloy10.1016/j.wear.2015.01.030 ↗
14. The effects of cooling conditions on surface integrity in machining of Ti6Al4V alloy10.1007/s00170-013-5477-9 ↗
15. Sphene silicate ceramic coatings on cpTi substrates: process upgrade10.1016/j.surfcoat.2017.05.018 ↗
16. Development of bioactive silicate-based glass-ceramics from preceramic polymer and fillers10.1016/j.jeurceramsoc.2014.09.020 ↗
17. W.C. Oliver, Measurement of hardness and elastic modulus by instrumented indentation: Advances in understanding and refinements to methodology, 2018.
18. ISO 14577-4:2016 · 2016
19. Temperature effects on the Ti6Al4V machinability using cooled gaseous nitrogen in semi - finishing turning10.1016/j.jmapro.2017.09.025 ↗
20. Surface integrity of dry machined titanium alloys10.1016/j.ijmachtools.2008.10.011 ↗
21. Surface integrity of finished turned Ti – 6Al – 4V alloy with PCD tools using conventional and high pressure coolant supplies10.1016/j.ijmachtools.2006.08.005 ↗
22. The kinetics of dynamic globularization during hot working of a two phase titanium alloy with starting lamellar microstructure10.1016/j.msea.2012.03.022 ↗
23. Coupling machining and heat treatment to enhance the wear behaviour of an Additive Manufactured Ti6Al4V titanium alloy10.1016/j.triboint.2017.07.004 ↗
24. Effects of TiO2 on microstructural, mechanical properties and in-vitro bioactivity of plasma sprayed yttria stabilised zirconia coatings for dental application10.1016/j.ceramint.2017.12.008 ↗
25. Elastic modulus of plasma-sprayed coatings determined by indentation and bend tests10.1016/S0040-6090(98)01491-6 ↗
26. A numerical/experimental study of contact damage in non-planar porcelain/metal bilayers10.1016/j.ijmecsci.2004.06.004 ↗
27. The influence of complex surface geometry on contact damage in curved brittle coatings10.1016/j.ijmecsci.2005.10.004 ↗