journal article·2009-06

Nondestructive Identification of Knot Types in Hand-Made Carpet. Part I: Feature Extraction from Grey Images

M. J. Karamad, M. Latifi, M. Amani-Tehran

Publisher page

Abstract

Knot (pile) formation has a very important role in evaluation and rating of hand-made carpets. Visual identification of carpet structural elements is impossible even for expert people. This research presents a nondestructive method for recognition of carpet knotting structure. It is based on X-ray radiography (mammography). Available X-ray beams create visible images from the internal structure of object in two dimensions. Primary radiological images are taken by radiography from hand-made carpets. They are then converted to structural recognizable images by employing different image processing techniques.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Industrial Vision Systems and Defect Detection · Image and Object Detection Techniques · Optical measurement and interference techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Lachkar, A., Benslimane, R., D’Orazio, L., Martuscelli, E.: Textile woven fabric recognition using Fourier image analysis techniques: Part II—Texture analysis for crossed-states detection. J. Tex. Inst. 96, 179–183 (2005)10.1533/joti.2004.0069 ↗
2. Xu, B.: Identifying fabric structures with fast Fourier transform techniques. Tex. Res. J. 66(8), 496–506 (1996)10.1177/004051759606600803 ↗
3. Carvalho, V., Cardoso, P., Belsley, M., Vasconcelos, R.M., Soares, F.O.: Yarn hairiness parameterization using a coherent signal processing technique. Sens. Actuators A Phys. 142(1), 217–224 (2008)10.1016/j.sna.2007.02.019 ↗
4. Su, C., Leu, C., Chern, H.: Image analysis of composite yarn cross sections. Tex. Res. J. 69(3), 203–207 (1999)10.1177/004051759906900307 ↗
5. Lien, H., Liu, C.: A method of inspecting non-woven basis weight using the exponential law of absorption and image processing. Tex. Res. J. 76(7), 547–558 (2006)10.1177/0040517506060141 ↗
6. Watanabe, A., Miwa, M., Takeno, A., Yokoi, T.: Fatigue behavior of aramid nonwoven fabrics under hot-press conditions. Part II: Geometric structure of fiber cross sections. Tex. Res. J. 65(5), 247–253 (1995)10.1177/004051759506500501 ↗
7. Conci, A., Proenc, C.B.: A fractal image analysis system for fabric inspection based on a box-counting method. Comput. Netw. ISDN Syst. 30, 1887–1895 (1998)10.1016/S0169-7552(98)00211-6 ↗
8. Mak, K.L., Peng, P.: An automated inspection system for textile fabrics based on Gabor filters. Robot. Comput.-Integr. Manuf. (2009, in press)
9. Van Steenlandt, W., Collet, D., Sette, S., Bernard, P., Lüning, R., Tezer, L., Böhland, K.H., Schulz, H.J.: Automatic assessment of carpet wear using image analysis and neural networks. Tex. Res. J. 66(9), 555–561 (1996)10.1177/004051759606600903 ↗
10. Wu, Y., Pourdeyhimi, B., Spivak, S.M.: Texture evaluation of carpets using image analysis. Tex. Res. J. 61(7), 407–419 (1991)10.1177/004051759106100708 ↗
11. Martin-Herrero, J., Germain, Ch.: Microstructure reconstruction of fibrous C/C composites from X-ray microtomography. Carbon 45(6), 1242–1253 (2007)10.1016/j.carbon.2007.01.021 ↗
12. Meske, R., Schnack, E.: Particular adaptation of X-ray diffraction to fiber reinforced composites. Mech. Mater. 35, 19–34 (2003)10.1016/S0167-6636(02)00184-9 ↗
13. Schilling, P.J., Karedla, B.R., Tatiparthi, A.K., Verges, M.A.: X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites. Compos. Sci. Technol. 65, 2071–2078 (2005)10.1016/j.compscitech.2005.05.014 ↗
14. Lashkia, V.: Defect detection in X-ray images using fuzzy reasoning. Image Vis. Comput. 19, 261–269 (2001)10.1016/S0262-8856(00)00075-5 ↗
15. Thornton, J.: Enhanced radiography for aircraft materials and components. Eng. Fail. Anal. 11, 207–220 (2004)10.1016/j.engfailanal.2003.05.008 ↗
16. Sun, Y., Bai, P., Sun, H., Zhou, P.: Real-time automatic detection of weld defects in steel pipe. NDT&E Int. 38, 522–528 (2005)10.1016/j.ndteint.2005.01.011 ↗
17. McFarlane, N.J.B., Speller, R.D., Bull, C.R., Tillett, R.D.: Detection of bone fragments in chicken meat using X-ray backscatter. Biosyst. Eng. 85(2), 185–199 (2003)10.1016/S1537-5110(03)00036-9 ↗
18. McFarlane, N.J.B., Bull, C.R., Tillett, R.D., Speller, R.D., Royle, G.J.: Time constraints on glass detection in food materials using Compton scattered X-rays. J. Agric. Eng. Res. 79(4), 407–418 (2001)10.1006/jaer.2001.0715 ↗
19. Neuhausler, U., Schneider, G.: Non-destructive high-resolution X-ray imaging of ULSI micro-electronics using keV X-ray microscopy in Zernike phase contrast. Microelectron. Eng. 83, 1043–1046 (2006)10.1016/j.mee.2006.01.225 ↗
20. Jakubek, J., Granjaa, C., Dammer, J., Hanus, R., Holy, T., Pospisil, S., Tykva, R., Uher, J., Vykydal, Z.: Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue. Nucl. Instrum. Methods Phys. Res. A 571(1), 69–72 (2007)10.1016/j.nima.2006.10.031 ↗
21. Jakubek, J., Holy, T., Jakubek, M., Vavrik, D., Vykydal, Z.: Experimental system for high resolution X-ray transmission radiography. Nucl. Instrum. Methods Phys. Res. 563, 278–281 (2006)10.1016/j.nima.2006.01.033 ↗
22. Koyama, T., Takano, H., Tsusaka, Y., Kagoshima, Y.: Tomographic quantitative phase measurement by hard X-ray micro-interferometer with 250 nm spatial resolution. Spectrochim. Acta, Part B: Atom. Spectrosc. 62(6), 603–607 (2007)10.1016/j.sab.2007.02.021 ↗
23. Potter, A.R., Austin, J.C., Ormerod, R.M., Haycock, P.W., Heywood, B.R., George, S.D.: X-ray images of defect formation in porcelain ceramics during drying. NDT&E Int. 36, 77–83 (2003)10.1016/S0963-8695(02)00088-9 ↗
24. Badel, E., Perre, P.: Using a digital X-ray imaging device to measure the swelling coefficients of a group of wood cells. NDT&E Int. 34, 345–353 (2001)10.1016/S0963-8695(00)00072-4 ↗
25. Neethirajan, S., Karunakaran, C., Jayas, D.S., White, N.D.G.: X-ray computed tomography image analysis to explain the airflow resistance differences in grain bulks. Biosyst. Eng. 94(4), 545–555 (2006)10.1016/j.biosystemseng.2006.04.013 ↗