journal article·2020-03

Wall Thickness Measurement of Pipes Using Digital Radiography and Three Wavelet Methods

Zeinab Kiapasha, Effat Yahaghi, Mahdi Mirzapour, Sajjad Monem, Jahangir Nekoei

Publisher page

Abstract

Digital X-ray radiography is a well established method for non-destructive detection of corrosion and measurement of wall thickness of pipes. Due mainly to the unavoidable detection of scattered X-rays as well as the ever-present system electronic noise, the quality of the acquired radiographs is often low; the quality can however be enhanced by applying various image processing methods. In this research, Wavelet Transform (WT), Gabor Filters (GF) and Shearlet Transform (ST) have been utilized in a background removing algorithm to achieve the required radiographic image quality improvement. The algorithm first decomposes the image into different levels using the WT, GF or the ST method, and the automatic thresholding level, which is based on Rayleigh distribution, is then applied. The output images (with the background removed) were then reconstructed by subtracting the modified component from the original radiograph. The results of the study showed that the reconstructed images yield significantly greater contrast than the original radiograph, the wall thickness measurements have higher precision and defect detection has greater specificity for defect in all regions. Also, the outcomes show that the algorithm has high analytical efficiency and is capable of accurately measuring pipe wall thicknesses and corrosion regions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Image and Signal Denoising Methods · Thermography and Photoacoustic Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Rakvin, M., Markučič, D., Hižman, B.: Evaluation of pipe wall thickness based on contrast measurement using computed radiography (cr). Proc. Eng. 69, 1216–1224 (2014)10.1016/j.proeng.2014.03.112 ↗
2. Carvalho, AAd, Suita, RCd S.B., Silva, RRd, Rebello, J.M.A.: Evaluation of the relevant features of welding defects in radiographic inspection. Mater. Res. 6(3), 427–432 (2003)10.1590/S1516-14392003000300019 ↗
3. Yun, H., Moon, S.-J., Oh, Y.-J.: Development of wall-thinning evaluation procedure for nuclear power plant piping–part 1: quantification of thickness measurement deviation. Nucl. Eng. Technol. 48(3), 820–830 (2016)10.1016/j.net.2016.01.020 ↗
4. Harara, W.: Deposit thickness measurement in pipes by tangential radiography using gamma ray sources. Russ. J. Nondestruct. Test. 44(11), 796–802 (2008)10.1134/S1061830908110090 ↗
5. Zscherpel, U., Ewert, U., Infanzon, S., Rastkhan, N., Vaidya, P., Einav, I., Ekinci, S.: Radiographic evaluation of corrosion and deposits in pipelines: results of an iaea co-ordinated research programme. In: Proceedings of European Conference on NDT, Berlin (2006)
6. Movafeghi, A., Mohammadzadeh, N., Yahaghi, E., Nekouei, J., Rostami, P., Moradi, G.: Defect detection of industrial radiography images of ammonia pipes by a sparse coding model. J. Nondestruct. Eval. 37(1), 3 (2018)10.1007/s10921-017-0458-9 ↗
7. Karimian, A.R., Torabian, M., Yazdchi, M.R.: Improvement of industrial radiography for defect detection of oil and gas pipelines in weld regions by image processing. J. Intell. Proced. Electr. Technol. 1(2), 51–58 (2010)
8. Shen, L., Bai, L.: A review on gabor wavelets for face recognition. Pattern Anal. Appl. 9(2–3), 273–292 (2006)10.1007/s10044-006-0033-y ↗
9. Lee, T.S.: Image representation using 2d gabor wavelets. IEEE Trans. Pattern Anal. Mach Intell. 10, 959–971 (1996)
10. Kutyniok, G., Lim, W.-Q., Reisenhofer, R.: Shearlab 3d: faithful digital shearlet transforms based on compactly supported shearlets, arXiv preprint arXiv:1402.5670
11. Barina, D.: Gabor wavelets in image processing, arXiv preprint arXiv:1602.03308
12. Mehrotra, R., Namuduri, K.R., Ranganathan, N.: Gabor filter-based edge detection. Pattern recognit. 25(12), 1479–1494 (1992)10.1016/0031-3203(92)90121-X ↗
13. Andersson, R.: Sparse representation and image classification with the shearlet transform
14. Yun, Y.: Riemannian manifold-based modeling and classification methods for video activities with applications to assisted living and smart home. Ph.D. thesis, Chalmers University of Technology, Gothenburg, Sweden (2016)
15. Labate, D., Lim, W.-Q., Kutyniok, G., Weiss, G.: Sparse multidimensional representation using shearlets. In: Wavelets XI, vol. 5914, p. 59140U. International Society for Optics and Photonics (2005)10.1117/12.613494 ↗
16. Grohs, P., Keiper, S., Kutyniok, G., Schafer, M.: $$\alpha $$-molecules. Appl. Comput. Harmonic Anal. 41(1), 297–336 (2014)10.1016/j.acha.2015.10.009 ↗
17. Easley, G., Labate, D., Lim, W.-Q.: Sparse directional image representations using the discrete shearlet transform. Appl. Comput. Harmonic Anal. 25(1), 25–46 (2008)10.1016/j.acha.2007.09.003 ↗
18. Easley, G.R., Labate, D., Lim, W.-Q.: Optimally sparse image representations using shearlets. In: 2006 Fortieth Asilomar Conference on Signals, Systems and Computers, ACSSC’06, pp. 974–978. IEEE (2006)10.1109/ACSSC.2006.354897 ↗
19. Kovesi, P.: Phase preserving denoising of images, signal 4(1)
20. I. 19232-5, Non-destructive testing—image quality of radiographs—Part 5: determination of the image unsharpness value using duplex wire-type image quality indicators. International Organization for Standardization, Switzerland (2013)
21. 16371-2, Non-destructive testing—industrial computed radiography with storage phosphor imaging plates—part 2: general principles for testing of metallic materials using X-rays and gamma rays. International Organization for Standardization, Switzerland (2017)
22. I. 16371-1, Non-destructive testing—image quality of radiographs—part 5: determination of the image unsharpness value using duplex wire-type image quality indicators. International Organization for Standardization, Switzerland (2011)