A pilot study to test the validity of a piezoelectric intra-splint force detector for monitoring of sleep bruxism in comparison to portable polysomnography
Source abstract
Abstract
PURPOSE: To test the validity of a force-based detection system (ISFD: intra-splint force detector) to record sleep bruxism (SB) in comparison to portable polysomnography (PSG). METHODS: Simultaneous portable PSG recordings with a masseter electromyography (EMG) channel and ISFD with a deformation-sensitive piezoelectric film were performed on six participants with definite SB. First, simulated bruxism behaviors (static clenching, grinding, tapping, and rhythmic clenching) were recorded using both EMG and ISFD. Using these data, interval and duration criteria for ISFD data conditioning were established. Then, portable PSG recordings were conducted with the ISFD during sleep. Using the above criteria, ISFD events were compared with EMG-based SB episodes (the gold standard), and the sensitivity and positive predictive value of ISFD events were calculated. Spearman's correlation coefficients between true-positive ISFD events and SB episodes were then calculated. RESULTS: Among the tested conditioning criteria, a 3-s interval combined with a 1-s duration was selected. The median sensitivity and positive predictive value for the ISFD were 0.861 and 0.585, respectively. The duration of true-positive ISFD events was correlated with that of EMG-based SB episodes (rho = 0.658, P < 0.01). CONCLUSION: ISFD has validity for SB detection and could be an alternative to single-channel EMG-based recordings.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Temporomandibular Joint Disorders · Muscle activation and electromyography studies · Musicians’ Health and Performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, School of Dentistry, Showa University
Funding
Japan Society for the Promotion of Science
References (28)
Show source-provided references
1. 1. Sateia MJ, Buysse DJ, Krystal AD, Neubauer DN, Heald JL (2017) Clinical practice guideline for the pharmacologic treatment of chronic insomnia in adults: an American Academy of Sleep Medicine clinical practice guideline. J Clin Sleep Med 13, 307-349.10.5664/jcsm.6470 ↗
2. 2. Abe S, Yamaguchi T, Rompré PH, De Grandmont P, Chen YJ, Lavigne GJ (2009) Tooth wear in young subjects: a discriminator between sleep bruxers and controls? Int J Prosthodont 22, 342-350.
3. 3. Yoshizawa S, Suganuma T, Takaba M, Ono Y, Sakai T, Yoshizawa A et al. (2014) Phasic jaw motor episodes in healthy subjects with or without clinical signs and symptoms of sleep bruxism: a pilot study. Sleep Breath 18, 187-193.10.1007/s11325-013-0868-6 ↗
4. 4. Yoshida Y, Suganuma T, Takaba M, Ono Y, Abe Y, Yoshizawa S et al. (2017) Association between patterns of jaw motor activity during sleep and clinical signs and symptoms of sleep bruxism. J Sleep Res 26, 415-421.10.1111/jsr.12481 ↗
5. 5. Beddis H, Pemberton M, Davies S (2018) Sleep bruxism: an overview for clinicians. Br Dent J 225, 497-501.10.1038/sj.bdj.2018.757 ↗
6. 6. Baba K, Haketa T, Sasaki Y, Ohyama T, Clark GT (2005) Association between masseter muscle activity levels recorded during sleep and signs and symptoms of temporomandibular disorders in healthy young adults. J Orofac Pain 19, 226-231.
7. 7. Manfredini D, Lobbezoo F (2010) Relationship between bruxism and temporomandibular disorders: a systematic review of literature from 1998 to 2008. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109, e26-50.10.1016/j.tripleo.2010.02.013 ↗
8. 8. Lobbezoo F, Ahlberg J, Raphael KG, Wetselaar P, Glaros AG, Kato T et al. (2018) International consensus on the assessment of bruxism: report of a work in progress. J Oral Rehabil 45, 837-844.10.1111/joor.12663 ↗
9. 9. Lavigne GJ, Rompré PH, Montplaisir JY (1996) Sleep bruxism: validity of clinical research diagnostic criteria in a controlled polysomnographic study. J Dent Res 75, 546-552.10.1177/00220345960750010601 ↗
10. 10. Stuginski-Barbosa J, Porporatti AL, Costa YM, Svensson P, Conti PC (2016) Diagnostic validity of the use of a portable single-channel electromyography device for sleep bruxism. Sleep Breath 20, 695-702.10.1007/s11325-015-1283-y ↗
11. 11. Garnick JJ (1975) Reproducibility of the electromyogram. J Dent Res 54, 867-871.10.1177/00220345750540042701 ↗
12. 12. Baba K, Clark GT, Watanabe T, Ohyama T (2003) Bruxism force detection by a piezoelectric film-based recording device in sleeping humans. J Orofac Pain 17, 58-64.
13. 13. Takeuchi H, Ikeda T, Clark GT (2001) A piezoelectric film-based intrasplint detection method for bruxism. J Prosthet Dent 86, 195-202.10.1067/mpr.2001.115487 ↗
14. 14. Dubé C, Rompré PH, Manzini C, Guitard F, de Grandmont P, Lavigne GJ (2004) Quantitative polygraphic controlled study on efficacy and safety of oral splint devices in tooth-grinding subjects. J Dent Res 83, 398-403.10.1177/154405910408300509 ↗
15. 15. Levendowski DJ, Ferini-Strambi L, Gamaldo C, Cetel M, Rosenberg R, Westbrook PR (2017) The accuracy, night-to-night variability, and stability of frontopolar sleep electroencephalography biomarkers. J Clin Sleep Med 13, 791-803.10.5664/jcsm.6618 ↗
16. 16. Miettinen T, Myllymaa K, Hukkanen T, Töyräs J, Sipilä K, Myllymaa S (2018) Home polysomnography reveals a first-night effect in patients with low sleep bruxism activity. J Clin Sleep Med 14, 1377-1386.10.5664/jcsm.7278 ↗
17. 17. Lobbezoo F, Ahlberg J, Glaros AG, Kato T, Koyano K, Lavigne GJ et al. (2013) Bruxism defined and graded: an international consensus. J Oral Rehabil 40, 2-4.10.1111/joor.12011 ↗
18. 18. Rompré PH, Daigle-Landry D, Guitard F, Montplaisir JY, Lavigne GJ (2007) Identification of a sleep bruxism subgroup with a higher risk of pain. J Dent Res 86, 837-842.10.1177/154405910708600906 ↗
19. 19. Nakamura H, Takaba M, Abe Y, Yoshizawa S, Suganuma T, Yoshida Y et al. (2019) Effects of a contingent vibratory stimulus delivered by an intra-oral device on sleep bruxism: a pilot study. Sleep Breath 23, 363-372.10.1007/s11325-019-01782-x ↗
20. 20. Harada T, Ichiki R, Tsukiyama Y, Koyano K (2006) The effect of oral splint devices on sleep bruxism: a 6-week observation with an ambulatory electromyographic recording device. J Oral Rehabil 33, 482-488.10.1111/j.1365-2842.2005.01576.x ↗
21. 21. Matsumoto H, Tsukiyama Y, Kuwatsuru R, Koyano K (2015) The effect of intermittent use of occlusal splint devices on sleep bruxism: a 4-week observation with a portable electromyographic recording device. J Oral Rehabil 42, 251-258.10.1111/joor.12251 ↗
22. 22. Lavigne GJ, Rompré PH, Poirier G, Huard H, Kato T, Montplaisir JY (2001) Rhythmic masticatory muscle activity during sleep in humans. J Dent Res 80, 443-448.10.1177/00220345010800020801 ↗
23. 23. Haketa T, Baba K, Akishige S, Fueki K, Kino K, Ohyama T (2003) Utility and validity of a new EMG-based bruxism detection system. Int J Prosthodont 16, 422-428.
24. 24. Nakazato Y, Takaba M, Abe Y, Nakamura H, Ohara H, Suganuma T et al. (2021) Effect of contingent vibratory stimulus via an oral appliance on sleep bruxism after the splint adaptation period. J Oral Rehabil 48, 901-908.10.1111/joor.13182 ↗
25. 25. Ohara H, Takaba M, Abe Y, Nakazato Y, Aoki R, Yoshida Y et al. (2021) Effects of vibratory feedback stimuli through an oral appliance on sleep bruxism: a 6-week intervention trial. Sleep Breath, Aug 9, doi: 10.1007/s11325-021-02460-7.10.1007/s11325-021-02460-7 ↗
26. 26. Maeda M, Yamaguchi T, Mikami S, Yachida W, Saito T, Sakuma T et al. (2020) Validity of single-channel masseteric electromyography by using an ultraminiature wearable electromyographic device for diagnosis of sleep bruxism. J Prosthodont Res 64, 90-97.10.1016/j.jpor.2019.04.003 ↗
27. 27. Yamaguchi T, Abe S, Rompré PH, Manzini C, Lavigne GJ (2012) Comparison of ambulatory and polysomnographic recording of jaw muscle activity during sleep in normal subjects. J Oral Rehabil 39, 2-10.10.1111/j.1365-2842.2011.02232.x ↗
28. 28. McAuliffe P, Kim JH, Diamond D, Lau KT, O’Connell BC (2015) A sleep bruxism detection system based on sensors in a splint - pilot clinical data. J Oral Rehabil 42, 34-39.10.1111/joor.12223 ↗