Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses
Source abstract
Abstract
Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry
Division of Dental Education, Dental Research Center, Nihon University School of Dentistry
Department of Fixed Prosthodontics, Nihon University School of Dentistry
Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
Funding
Japanese Association for Dental Science
References (32)
Show source-provided references
1. 1. Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204, 505-511.10.1038/sj.bdj.2008.350 ↗
2. 2. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y (2009) A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 28, 44-56.10.4012/dmj.28.44 ↗
3. 3. Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions--an in-vitro study. Int J Comput Dent 14, 11-21.
4. 4. Ender A, Mehl A (2015) In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions. Quintessence Int 46, 9-17.
5. 5. Ender A, Attin T, Mehl A (2016) In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent 115, 313-320.10.1016/j.prosdent.2015.09.011 ↗
6. 6. Ender A, Zimmermann M, Attin T, Mehl A (2016) In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Investig 20, 1495-1504.10.1007/s00784-015-1641-y ↗
7. 7. Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17, 1759-1764.10.1007/s00784-012-0864-4 ↗
8. 8. Pedroche LO, Bernardes SR, Leão MP, Kintopp CC, Correr GM, Ornaghi BP et al. (2016) Marginal and internal fit of zirconia copings obtained using different digital scanning methods. Braz Oral Res 30, e113.10.1590/1807-3107BOR-2016.vol30.0113 ↗
9. 9. An S, Kim S, Choi H, Lee JH, Moon HS (2014) Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner. J Prosthet Dent 112, 1171-1175.10.1016/j.prosdent.2013.12.024 ↗
10. 10. Ng J, Ruse D, Wyatt C (2014) A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 112, 555-560.10.1016/j.prosdent.2013.12.002 ↗
11. 11. Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study. Dent Mater 30, 400-407.10.1016/j.dental.2014.01.006 ↗
12. 12. Almeida e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LC et al. (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18, 515-523.10.1007/s00784-013-0987-2 ↗
13. 13. Ueda K, Beuer F, Stimmelmayr M, Erdelt K, Keul C, Güth JF (2016) Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions. Clin Oral Investig 20, 283-289.10.1007/s00784-015-1513-5 ↗
14. 14. Shembesh M, Ali A, Finkelman M, Weber HP, Zandparsa R (2017) An in vitro comparison of the marginal adaptation accuracy of CAD/CAM restorations using different impression systems. J Prosthodont 26, 581-586.10.1111/jopr.12446 ↗
15. 15. Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38, 553-559.10.1016/j.jdent.2010.03.015 ↗
16. 16. Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 43, 201-208.10.1016/j.jdent.2014.12.007 ↗
17. 17. Ahrberg D, Lauer HC, Ahrberg M, Weigl P (2016) Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig 20, 291-300.10.1007/s00784-015-1504-6 ↗
18. 18. Zarauz C, Valverde A, Martinez-Rus F, Hassan B, Pradies G (2016) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions. Clin Oral Investig 20, 799-806.10.1007/s00784-015-1590-5 ↗
19. 19. Berrendero S, Salido MP, Valverde A, Ferreiroa A, Pradíes G (2016) Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns. Clin Oral Investig 20, 2403-2410.10.1007/s00784-016-1714-6 ↗
20. 20. Rödiger M, Heinitz A, Bürgers R, Rinke S (2017) Fitting accuracy of zirconia single crowns produced via digital and conventional impressions--a clinical comparative study. Clin Oral Investig 21, 579-587.10.1007/s00784-016-1924-y ↗
21. 21. Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health, Jan 30, doi/ 10.1186/1472-6831-14-10.10.1186/1472-6831-14-10 ↗
22. 22. Patzelt SB, Lamprinos C, Stampf S, Att W (2014) The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc 145, 542-551.10.14219/jada.2014.23 ↗
23. 23. Gjelvold B, Chrcanovic BR, Korduner EK, Collin-Bagewitz I, Kisch J (2016) Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial. J Prosthodont 25, 282-287.10.1111/jopr.12410 ↗
24. 24. Gherlone E, Mandelli F, Capparè P, Pantaleo G, Traini T, Ferrini F (2014) A 3 years retrospective study of survival for zirconia-based single crowns fabricated from intraoral digital impressions. J Dent 42, 1151-1155.10.1016/j.jdent.2014.06.002 ↗
25. 25. Selz CF, Bogler J, Vach K, Strub JR, Guess PC (2015) Veneered anatomically designed zirconia FDPs resulting from digital intraoral scans: preliminary results of a prospective clinical study. J Dent 43, 1428-1435.10.1016/j.jdent.2015.10.017 ↗
26. 26. Flügge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 144, 471-478.10.1016/j.ajodo.2013.04.017 ↗
27. 27. Rudolph H, Salmen H, Moldan M, Kuhn K, Sichwardt V, Wöstmann B et al. (2016) Accuracy of intraoral and extraoral digital data acquisition for dental restorations. J Appl Oral Sci 24, 85-94.10.1590/1678-775720150266 ↗
28. 28. Güth JF, Runkel C, Beuer F, Stimmelmayr M, Edelhoff D, Keul C (2017) Accuracy of five intraoral scanners compared to indirect digitalization. Clin Oral Investig 21, 1445-1455.10.1007/s00784-016-1902-4 ↗
29. 29. Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems. Clin Oral Investig 17, 2119-2125.10.1007/s00784-013-0923-5 ↗
30. 30. Tamim H, Skjerven H, Ekfeldt A, Rønold HJ (2014) Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions. Int J Prosthodont 27, 331-337.10.11607/ijp.3607 ↗
31. 31. Shimizu S, Shinya A, Kuroda S, Gomi H (2017) The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses. Dent Mater J 36, 402-407.10.4012/dmj.2016-326 ↗
32. 32. Monaco C, Ragazzini N, Scheda L, Evangelisti E (2017) A fully digital approach to replicate functional and aesthetic parameters in implant-supported full-arch rehabilitation. J Prosthodont Res, Nov 27, doi: 10.1016/j.jpor.2017.10.005.10.1016/j.jpor.2017.10.005 ↗