journal article·2010Open access

Current status of zirconia-based fixed restorations

Futoshi Komine, Markus B. Blatz, Hideo Matsumura

Journal of Oral Science· Volume 52· Issue 4

Abstract

Zirconium dioxide (zirconia) ceramics are currently used for fixed restorations as a framework material due to their mechanical and optical properties. This review article describes the current status of zirconia-based fixed restorations, including results of current in vitro studies and the clinical performance of these restorations. Adaptation of zirconia-based restorations fabricated with CAD/CAM technology is within an acceptable range to meet clinical requirements. In terms of fracture resistance, zirconia-based fixed partial dentures (FPDs) have the potential to withstand physiological occlusal forces applied in the posterior region, and therefore provide interesting alternatives to metal-ceramic restorations. Clinical evaluations have indicated an excellent clinical survival of zirconia-based FPDs and crown restorations. However, some clinical studies have revealed a high incidence of chipping of veneered porcelain. Full-coverage zirconia-based restorations with adequate retention do not require resin bonding for definitive cementation. Resin bonding, however, may be advantageous in certain clinical situations and is a necessity for bonded restorations, such as resin-bonded FPDs. Combined surface treatment using airborne particle abrasion and specific adhesives with a hydrophobic phosphate monomer are currently reliable for bonding to zirconia ceramics. Further clinical and in vitro studies are needed to obtain long-term clinical information on zirconia-based restorations.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Research and COVID-19

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (82)

Show source-provided references
1. 10.1002/jbm.82023010510.1002/jbm.820230105 ↗
2. 10.1002/jbm.82028051210.1002/jbm.820280512 ↗
3. 10.1038/258703a010.1038/258703a0 ↗
4. 10.1111/j.1749-6632.1988.tb38516.x10.1111/j.1749-6632.1988.tb38516.x ↗
5. 5. Winchester LJ (1991) Bond strengths of five different ceramic brackets: an in vitro study. Eur J Orthod 13, 293-305.10.1093/ejo/13.4.293 ↗
6. 10.1111/j.1708-8240.1995.tb00565.x10.1111/j.1708-8240.1995.tb00565.x ↗
7. 7. Luthardt RG, Sandkuhl O, Reitz B (1999) Zirconia-TZP and alumina – advanced technologies for the manufacturing of single crowns. Eur J Prosthodont Restor Dent 7, 113-119.
8. 8. Sjölin R, Sundh A, Bergman M (1999) The Decim system for the production of dental restorations. Int J Comput Dent 2, 197-207.
9. 9. Witkowski S (2005) (CAD-)/CAM in dental technology. Quintessence Dent Technol 28, 169-184.
10. 10. Vagkopoulou T, Koutayas SO, Koidis P, Strub JR (2009) Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent 4, 130-151.
11. 11. Filser F, Kocher P, Weibel F, Lüthy H, Schärer P, Gauckler LJ (2001) Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 4, 89-106.
12. 12. Suttor D, Bunke K, Hoescheler S, Hauptmann H, Hertlein G (2001) LAVA – the system for all-ceramic ZrO2 crown and bridge frameworks. Int J Comput Dent 4, 195-206.
13. 10.1111/j.1365-2842.2005.01446.x10.1111/j.1365-2842.2005.01446.x ↗
14. 10.4012/dmj.26.65910.4012/dmj.26.659 ↗
15. 10.4012/dmj.26.82010.4012/dmj.26.820 ↗
16. 16. Iwai T, Komine F, Kobayashi K, Saito A, Matsumura H (2008) Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings. Acta Odontol Scand 66, 214-218.10.1080/00016350802139833 ↗
17. 17. Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 40, 243-250.
18. 18. Comlekoglu M, Dundar M, Özcan M, Gungor M, Gokce B, Artunc C (2009) Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent 34, 586-592.10.2341/08-076-L ↗
19. 19. Bindl A, Mörmann WH (2007) Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent 27, 567-575.
20. 10.1016/j.dental.2008.04.01810.1016/j.dental.2008.04.018 ↗
21. 21. Kohorst P, Junghanns J, Dittmer MP, Borchers L, Stiesch M (2010) Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy. Clin Oral Investig. doi: 10.1007/s00784-010-0415-9.10.1007/s00784-010-0415-9 ↗
22. 10.1111/j.1600-0722.2009.00622.x10.1111/j.1600-0722.2009.00622.x ↗
23. 23. Att W, Komine F, Gerds T, Strub JR (2009) Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. J Prosthet Dent 101, 239-247.10.1016/S0022-3913(09)60047-0 ↗
24. 24. Komine F, Gerds T, Witkowski S, Strub JR (2005) Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks. Acta Odontol Scand 63, 361-366.10.1080/00016350500264313 ↗
25. 25. Vigolo P, Fonzi F (2008) An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont 17, 621-626.10.1111/j.1532-849X.2008.00366.x ↗
26. 26. Dittmer MP, Borchers L, Stiesch M, Kohorst P (2009) Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process. Acta Biomater 5, 3231-3239.10.1016/j.actbio.2009.04.025 ↗
27. 27. Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M (2010) Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 37, 283-291.10.1111/j.1365-2842.2009.02053.x ↗
28. 28. Isgrò G, Wang H, Kleverlaan CJ, Feilzer AJ (2005) The effects of thermal mismatch and fabrication procedures on the deflection of layered all-ceramic discs. Dent Mater 21, 649-655.10.1016/j.dental.2004.09.001 ↗
29. 29. Gonzalo E, Suárez MJ, Serrano B, Lozano JF (2008) Marginal fit of zirconia posterior fixed partial dentures. Int J Prosthodont 21, 398-399.
30. 30. Beuer F, Naumann M, Gernet W, Sorensen JA (2009) Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig 13, 343-349.10.1007/s00784-008-0224-6 ↗
31. 31. Gonzalo E, Suárez MJ, Serrano B, Lozano JF (2009) A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 102, 378-384.10.1016/S0022-3913(09)60198-0 ↗
32. 32. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H (2001) Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 14, 231-238.
33. 10.1016/j.dental.2004.07.01310.1016/j.dental.2004.07.013 ↗
34. 34. Att W, Grigoriadou M, Strub JR (2007) ZrO2 three-unit fixed partial dentures: comparison of failure load before and after exposure to a mastication simulator. J Oral Rehabil 34, 282-290.10.1111/j.1365-2842.2006.01705.x ↗
35. 10.1080/0001635060085623210.1080/00016350600856232 ↗
36. 10.1016/j.dental.2005.11.00610.1016/j.dental.2005.11.006 ↗
37. 37. Wolfart S, Ludwig K, Uphaus A, Kern M (2007) Fracture strength of all-ceramic posterior inlay-retained fixed partial dentures. Dent Mater 23, 1513-1520.10.1016/j.dental.2006.12.006 ↗
38. 38. Plengsombut K, Brewer JD, Monaco EA Jr, Davis EL (2009) Effect of two connector designs on the fracture resistance of all-ceramic core materials for fixed dental prostheses. J Prosthet Dent 101, 166-173.10.1016/S0022-3913(09)60022-6 ↗
39. 39. Bahat Z, Mahmood DJ, Vult von Steyern P (2009) Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design. Swed Dent J 33, 149-159.
40. 40. Vult von Steyern P (2005) All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems. Swed Dent J Suppl, 1-69.
41. 10.1111/j.1365-2842.2004.01437.x10.1111/j.1365-2842.2004.01437.x ↗
42. 42. Larsson C, Holm L, Lövgren N, Kokubo Y, Vult von Steyern P (2007) Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil 34, 702-709.10.1111/j.1365-2842.2007.01770.x ↗
43. 43. Mehl C, Ludwig K, Steiner M, Kern M (2010) Fracture strength of prefabricated all-ceramic posterior inlay-retained fixed dental prostheses. Dent Mater 26, 67-75.10.1016/j.dental.2009.07.013 ↗
44. 44. Kern M (2005) Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures. Quintessence Int 36, 141-147.
45. 10.2334/josnusd.47.13910.2334/josnusd.47.139 ↗
46. 46. Ries S, Wolz J, Richter EJ (2006) Effect of design of all-ceramic resin-bonded fixed partial dentures on clinical survival rate. Int J Periodontics Restorative Dent 26, 143-149.
47. 10.1007/s00784-009-0254-810.1007/s00784-009-0254-8 ↗
48. 48. Zahran M, El-Mowafy O, Tam L, Watson PA, Finer Y (2008) Fracture strength and fatigue resistance of all-ceramic molar crowns manufactured with CAD/CAM technology. J Prosthodont 17, 370-377.10.1111/j.1532-849X.2008.00305.x ↗
49. 49. Reich S, Petschelt A, Lohbauer U (2008) The effect of finish line preparation and layer thickness on the failure load and fractography of ZrO2 copings. J Prosthet Dent 99, 369-376.10.1016/S0022-3913(08)60085-2 ↗
50. 10.1016/S0109-5641(98)00011-610.1016/S0109-5641(98)00011-6 ↗
51. 51. Wegner SM, Kern M (2000) Long-term resin bond strength to zirconia ceramic. J Adhes Dent 2, 139-147.
52. 52. Wegner SM, Gerdes W, Kern M (2002) Effect of different artificial aging conditions on ceramic-composite bond strength. Int J Prosthodont 15, 267-272.
53. 10.1016/S0109-5641(03)00019-810.1016/S0109-5641(03)00019-8 ↗
54. 54. Piwowarczyk A, Lauer HC, Sorensen JA (2005) The shear bond strength between luting cements and zirconia ceramics after two pre-treatments. Oper Dent 30, 382-388.
55. 10.1016/j.prosdent.2006.03.01610.1016/j.prosdent.2006.03.016 ↗
56. 56. Blatz MB, Chiche G, Holst S, Sadan A (2007) Influence of surface treatment and simulated aging on bond strengths of luting agents to zirconia. Quintessence Int 38, 745-753.
57. 10.1016/j.prosdent.2004.02.00110.1016/j.prosdent.2004.02.001 ↗
58. 58. Nakayama D, Koizumi H, Komine F, Blatz MB, Tanoue N, Matsumura H (2010) Adhesive bonding of zirconia with single-liquid acidic primers and a tri-n-butylborane initiated acrylic resin. J Adhes Dent 12, 305-310.
59. 10.1016/j.dental.2005.02.00510.1016/j.dental.2005.02.005 ↗
60. 60. Kitayama S, Nikaido T, Ikeda M, Alireza S, Miura H, Tagami J (2010) Internal coating of zirconia restoration with silica-based ceramic improves bonding of resin cement to dental zirconia ceramic. Biomed Mater Eng 20, 77-87.10.3233/BME-2010-0617 ↗
61. 10.1016/S0022-3913(07)60123-110.1016/S0022-3913(07)60123-1 ↗
62. 62. Rosentritt M, Behr M, Thaller C, Rudolph H, Feilzer A (2009) Fracture performance of computer-aided manufactured zirconia and alloy crowns. Quintessence Int 40, 655-662.
63. 10.1016/j.prosdent.2006.08.01010.1016/j.prosdent.2006.08.010 ↗
64. 64. Sailer I, Fehér A, Filser F, Lüthy H, Gauckler LJ, Schärer P, Franz Hämmerle CH (2006) Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 37, 685-693.
65. 65. Sailer I, Fehér A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20, 383-388.
66. 66. Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21, 217-222.
67. 67. Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21, 223-227.
68. 68. Crisp RJ, Cowan AJ, Lamb J, Thompson O, Tulloch N, Burke FJ (2008) A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results. Br Dent J 205, 477-482.10.1038/sj.bdj.2008.937 ↗
69. 69. Edelhoff D, Florian B, Florian W, Johnen C (2008) HIP zirconia fixed partial dentures – clinical results after 3 years of clinical service. Quintessence Int 39, 459-471.
70. 70. Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O (2009) Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 36, 610-615.10.1111/j.1365-2842.2009.01969.x ↗
71. 71. Wolfart S, Harder S, Eschbach S, Lehmann F, Kern M (2009) Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design. Eur J Oral Sci 117, 741-749.10.1111/j.1600-0722.2009.00693.x ↗
72. 72. Sailer I, Gottnerb J, Känelb S, Hämmerle CH (2009) Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 22, 553-560.
73. 73. Çehreli MC, Kökat AM, Akça K (2009) CAD/CAM zirconia vs. slip-cast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial. J Appl Oral Sci 17, 49-55.10.1590/S1678-77572009000100010 ↗
74. 74. Schmitt J, Holst S, Wichmann M, Reich S, Göllner M, Hamel J (2009) Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up. Int J Prosthodont 22, 597-603.
75. 10.1016/j.jdent.2009.06.00210.1016/j.jdent.2009.06.002 ↗
76. 76. Beuer F, Edelhoff D, Gernet W, Sorensen JA (2009) Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig 13, 445-451.10.1007/s00784-009-0249-5 ↗
77. 77. Beuer F, Stimmelmayr M, Gernet W, Edelhoff D, Güh JF, Naumann M (2010) Prospective study of zirconia-based restorations: 3-year clinical results. Quintessence Int 41, 631-637.
78. 78. Roediger M, Gersdorff N, Huels A, Rinke S (2010) Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont 23, 141-148.
79. 79. Koutayas SO, Vagkopoulou T, Pelekanos S, Koidis P, Strub JR (2009) Zirconia in dentistry: part 2. Evidence-based clinical breakthrough. Eur J Esthet Dent 4, 348-380.
80. 80. Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings – a new fabrication mode for all-ceramic restorations. Dent Mater 25, 121-128.10.1016/j.dental.2008.04.019 ↗
81. 81. Marchack BW, Futatsuki Y, Marchack CB, White SN (2008) Customization of milled zirconia copings for all-ceramic crowns: a clinical report. J Prosthet Dent 99, 169-173.10.1016/S0022-3913(08)00028-0 ↗
82. 82. Kobayashi K, Komine F, Blatz MB, Saito A, Koizumi H, Matsumura H (2009) Influence of priming agents on the short-term bond strength of an indirect composite veneering material to zirconium dioxide ceramic. Quintessence Int 40, 545-551.