Depth of cure of high-viscosity bulk-fill and conventional resin composites using varying irradiance exposures with a light-emitting diode curing unit
Source abstract
Abstract
The purpose of this study was to determine the depth of cure (DOC) of three resin-based composites (RBCs) using varying irradiance exposures with a corded light-emitting diode curing unit. DOCs for Filtek Z250, TPH Spectra, and Tetric EvoCeram Bulk Fill were determined using the International Organization for Standardization (ISO) Standard 4049. The RBCs were light-polymerized using three different power modes and manufacturer-recommended curing times. Irradiance was determined using a spectrometer sensor and the total energy density was calculated for each power mode and concomitant polymerization time. The DOC data were analyzed with a two-way analysis of variance and Tukey's post hoc test. Tetric EvoCeram Bulk Fill produced significantly greater DOCs than TPH and Z250 (P < 0.05) for all three power mode settings. Overall, the DOC of Tetric EvoCeram Bulk Fill was greater than those of TPH and Z250 at all power settings, but the individual RBCs did not show a significant DOC difference among the three power settings (P > 0.05).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Photopolymerization techniques and applications · Additive Manufacturing and 3D Printing Technologies · Nanofabrication and Lithography Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of General Dentistry, Creighton University School of Dentistry
References (20)
Show source-provided references
1. 1. Yap AU, Wong NY, Siow KS (2003) Composite cure and shrinkage associated with high intensity curing light. Oper Dent 28, 357-364.
2. 2. Pearson GJ, Longman CM (1989) Water sorption and solubility of resin-based materials following inadequate polymerization by a visible-light curing system. J Oral Rehab 16, 57-61.10.1111/j.1365-2842.1989.tb01317.x ↗
3. 3. International Organization for Standardization (2009) Dentistry-polymer-based restorative materials. ISO 4049:2009, Geneva, Switzerland.
4. 4. Tiba A, Zeller GG, Estrich CG, Hong A (2013) A laboratory evaluation of bulk-fill verus traditional multi-increment-fill resin-based composites. J Am Dent Assoc 144, 1182-1183.10.14219/jada.archive.2013.0040 ↗
5. 5. Ferracane JL, Aday P, Matsumoto H, Marker VA (1986) Relationship between shade and depth of cure for light-activated dental composite resins. Dent Mater 2, 80-84.10.1016/S0109-5641(86)80057-4 ↗
6. 6. Santos GB, Medeiros IS, Fellows CE, Muench A, Braga RR (2007) Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-raman spectroscopy. Oper Dent 31, 79-83.10.2341/06-26 ↗
7. 7. Moore BK, Platt JA, Borges G, Chu T-MG, Katsilieri I (2008) Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades. Oper Dent 33, 408-412.10.2341/07-104 ↗
8. 8. Pollington S, Kahakachchi N, Van Noort R (2009) The influence of plastic light cure sheaths on the hardness of resin composite. Oper Dent 34, 741-745.10.2341/09-024-L ↗
9. 9. Erickson RL, Barkmeier WW (2017) Effect of mold diameter on the depth of cure of a resin-based composite material. Eur J Oral Sci 125, 88-92.10.1111/eos.12325 ↗
10. 10. Uhl A, Volpel A, Sigusch BW (2006) Influence of heat from light curing units and dental composite polymerization on cells in vitro. J Dent 34, 298-306.10.1016/j.jdent.2005.07.004 ↗
11. 11. Jandt KD, Mills RW (2013) A brief history of LED photopolymerization. Dent Mater 29, 605-617.10.1016/j.dental.2013.02.003 ↗
12. 12. Mousavinasab SM, Meyers I (2011) Comparison of depth of cure, hardness and heat generation of LED and high intensity QTH light sources. Eur J Dent 5, 299-304.10.1055/s-0039-1698895 ↗
13. 13. Shortall AC, Felix CJ, Watts DC (2015) Robust spectrometer-based methods for characterizing radiant exitance of dental LED lightcuring units. Dent Mater 31, 339-350.10.1016/j.dental.2015.02.012 ↗
14. 14. Harlow JE, Sullivan B, Shortall AC, Labrie D, Price RB (2016) Characterizing the output settings of dental curing lights. J Dent 44, 20-26.10.1016/j.jdent.2015.10.019 ↗
15. 15. Selig D, Haenel T, Hausnerová B, Moeginger B, Labrie D, Sullivan B et al. (2015) Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values. Dent Mater 31, 583-593.10.1016/j.dental.2015.02.010 ↗
16. 16. Fan PL, Schumacher RM, Azzolin K, Geary R, Eichmiller FC (2002) Curing-light intensity and depth of cure of resin-based composites tested according to international standards. JADA 133, 429-434.10.14219/jada.archive.2002.0200 ↗
17. 17. Nomoto R, Asada M, McCabe JF, Hirano S (2006) Light exposure required for optimum conversion of light activated resin systems. Dent Mater 22, 1135-1142.10.1016/j.dental.2005.10.011 ↗
18. 18. AlQahtani MQ, Michaud PL, Sullivan B, Labrie D, Michaud MM, Price RB (2015) Effect of high irradiance on depth of cure of a conventional and a bulk fill resin-based composite. Oper Dent 40, 662-672.10.2341/14-244-L ↗
19. 19. Menees TS, Lin CP, Kojic DD, Burgess JO, Lawson NC (2015) Depth of cure of bulk fill composites with monowave and polywave curing lights. Am J Dent 28, 357-361.
20. 20. Erickson RL, Barkmeier WW (2014) Curing characteristics of a composite-part 2: the effect of curing configuration on depth and distribution of cure. Dent Mater 30, e134-145.