journal article·2021Open access

Influence of pre-drilling diameter on the stability of orthodontic anchoring screws in the mid-palatal area

Yasuki Uchida, Yasuhiro Namura, Mizuki Inaba, Ayaka Osada, Tasku Charleston-Coad, Yoshiki Nakamura, Mitsuru Motoyoshi

Journal of Oral Science· Volume 63· Issue 3

Abstract

PURPOSE: The aim of this study was to investigate the stability of orthodontic anchor screws (OASs) in the mid-palatal area according to pre-drilling diameter. METHODS: The success rate of 161 OASs (83 patients, φ2.0 mm, 6.0 mm in length) placed in a corresponding area to the mesial and distal borders of the first molar (mesial zone and distal zone) was assessed according to placement location and pre-drilling diameter (1.2 and 1.5 mm). Placement torque values from 73 OASs with a pre-drilling diameter of 1.2 mm were compared between success and failure groups. RESULTS: The success rates of OASs pre-drilled with φ1.2 and 1.5 mm were 94.5% and 83.0%, respectively (P < 0.05); corresponding rates in the mesial zone were 100.0% and 77.3% (P < 0.005), and those in the distal zone were 89.2% and 88.6%, respectively. Placement torques of OASs predrilled with φ1.2 mm in the success and failure groups were 25.9 and 19.2 N·cm, respectively (P < 0.05). CONCLUSION: A smaller pre-drilling diameter was associated with a higher success rate of OASs in the mid-palatal area, especially in the mesial zone. When pre-drilling diameter of 1.2 mm was used for φ2.0 mm OAS, greater placement torque was indicative of greater OAS stability.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, and Division of Clinical Research, Dental Research Center, Nihon University School of Dentistry

Department of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry

References (26)

Show source-provided references
1. 1. Gintautaitė G, Gaidytė A (2017) Surgery-related factors affecting the stability of orthodontic mini implants screwed in alveolar process interdental spaces: a systematic literature review. Stomatologija 19, 10-18.
2. 2. Uchida Y, Motoyoshi M, Namura Y, Shimizu N (2017) Three-dimensional evaluation of the location of the mandibular canal using cone-beam computed tomography for orthodontic anchorage devices. J Oral Sci 59, 257-262.10.2334/josnusd.16-0513 ↗
3. 3. Mohammed H, Wafaie K, Rizk MZ, Almuzian M, Sosly R, Bearn DR (2018) Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis. Prog Orthod 19, 36.10.1186/s40510-018-0225-1 ↗
4. 4. Stockmann P, Schlegel KA, Srour S, Neukam FW, Fenner M, Felszeghy E (2009) Which region of the median palate is a suitable location of temporary orthodontic anchorage devices? A histomorphometric study on human cadavers aged 15-20 years. Clin Oral Implants Res 20, 306-312.10.1111/j.1600-0501.2008.01647.x ↗
5. 5. Kim YH, Yang SM, Kim S, Lee JY, Kim KE, Gianelly AA et al. (2010) Midpalatal miniscrews for orthodontic anchorage: factors affecting clinical success. Am J Orthod Dentofacial Orthop 137, 66-72.10.1016/j.ajodo.2007.11.036 ↗
6. 6. Rodriguez JC, Suarez F, Chan HL, Padial-Molina M, Wang HL (2014) Implants for orthodontic anchorage: success rates and reasons of failures. Implant Dent 23, 155-161.10.1097/ID.0000000000000048 ↗
7. 7. Tepedino M, Masedu F, Chimenti C (2017) Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study. Head Face Med 13, 10.10.1186/s13005-017-0143-3 ↗
8. 8. Suzuki M, Deguchi T, Watanabe H, Seiryu M, Iikubo M, Sasano T et al. (2013) Evaluation of optimal length and insertion torque for miniscrews. Am J Orthod Dentofacial Orthop 144, 251-259.10.1016/j.ajodo.2013.03.021 ↗
9. 9. Watanabe T, Miyazawa K, Fujiwara T, Kawaguchi M, Tabuchi M, Goto S (2017) Insertion torque and periotest values are important factors predicting outcome after orthodontic miniscrew placement. Am J Orthod Dentofacial Orthop 152, 483-488.10.1016/j.ajodo.2017.01.026 ↗
10. 10. Ichinohe M, Motoyoshi M, Inaba M, Uchida Y, Kaneko M, Matsuike R et al. (2019) Risk factors for failure of orthodontic mini-screws placed in the median palate. J Oral Sci 61, 13-18.10.2334/josnusd.17-0377 ↗
11. 11. Suzuki EY, Suzuki B (2011) Placement and removal torque values of orthodontic miniscrew implants. Am J Orthod Dentofacial Orthop 139, 669-678.10.1016/j.ajodo.2010.11.017 ↗
12. 12. Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N (2006) Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17, 109-114.10.1111/j.1600-0501.2005.01211.x ↗
13. 13. Wilmes B, Rademacher C, Olthoff G, Drescher D (2006) Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67, 162-174.10.1007/s00056-006-0611-z ↗
14. 14. Wilmes B, Ottenstreuer S, Su YY, Drescher D (2008) Impact of implant design on primary stability of orthodontic mini-implants. J Orofac Orthop 69, 42-50.10.1007/s00056-008-0727-4 ↗
15. 15. Uesugi S, Kokai S, Kanno Z, Ono T (2018) Stability of secondarily inserted orthodontic miniscrews after failure of the primary insertion for maxillary anchorage: maxillary buccal area vs midpalatal suture area. Am J Orthod Dentofacial Orthop 153, 54-60.10.1016/j.ajodo.2017.05.024 ↗
16. 16. Kim HJ, Yun HS, Park HD, Kim DH, Park YC (2006) Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 130, 177-182.10.1016/j.ajodo.2004.12.024 ↗
17. 17. Asscherickx K, Vannet BV, Bottenberg P, Wehrbein H, Sabzevar MM (2010) Clinical observations and success rates of palatal implants. Am J Orthod Dentofacial Orthop 137, 114-122.10.1016/j.ajodo.2008.02.022 ↗
18. 18. Becker K, Pliska A, Busch C, Wilmes B, Wolf M, Drescher D (2018) Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis. Int J Implant Dent 4, 35.10.1186/s40729-018-0144-4 ↗
19. 19. Kakali L, Alharbi M, Pandis N, Gkantidis N, Kloukos D (2019) Success of palatal implants or mini-screws placed median or paramedian for the reinforcement of anchorage during orthodontic treatment: a systematic review. Eur J Orthod 41, 9-20.10.1093/ejo/cjy015 ↗
20. 20. Hung E, Oliver D, Kim KB, Kyung HM, Buschang PH (2012) Effects of pilot hole size and bone density on miniscrew implants’ stability. Clin Implant Dent Relat Res 14, 454-460.10.1111/j.1708-8208.2010.00269.x ↗
21. 21. Uemura M, Motoyoshi M, Yano S, Sakaguchi M, Igarashi Y, Shimizu N (2012) Orthodontic mini-implant stability and the ratio of pilot hole implant diameter. Eur J Orthod 34, 52-56.10.1093/ejo/cjq157 ↗
22. 22. Baumgaertel S (2009) Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults. Am J Orthod Dentofacial Orthop 136, 104-108.10.1016/j.ajodo.2008.11.020 ↗
23. 23. Sumer AP, Caliskan A, Uzun C, Karoz TB, Sumer M, Cankaya S (2016) The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography. Int J Oral Maxillofac Surg 45, 216-220.10.1016/j.ijom.2015.09.012 ↗
24. 24. Bourassa C, Hosein YK, Pollmann SI, Galil K, Bohay RN, Holdsworth DW et al. (2018) In-vitro comparison of different palatal sites for orthodontic miniscrew insertion: Effect of bone quality and quantity on primary stability. Am J Orthod Dentofacial Orthop 154, 809-819.10.1016/j.ajodo.2018.02.010 ↗
25. 25. Moon SH, Park SH, Lim WH, Chun YS (2010) Palatal bone density in adult subjects: implications for mini-implant placement. Angle Orthod 80, 137-144.10.2319/011909-40.1 ↗
26. 26. Wilmes B, Panayotidis A, Drescher D (2011) Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study. Eur J Orthod 33, 396-401.10.1093/ejo/cjq151 ↗