Effect of CAD-CAM block material and thickness on the translucency parameter and polymerization of light-cured resin cement
Source abstract
Abstract
PURPOSE: This study assessed the association of computer-aided design-computer-aided manufacturing (CAD-CAM) block material and thickness with the translucency parameter and polymerization of a light-cured resin cement. METHODS: Specimens were prepared from CAD-CAM blocks (Lava Ultimate, IPS Empress CAD, Celtra Duo) with thicknesses of 0.5, 1, and 2 mm (n = 10 each). The translucency parameter (TP) of the blocks was calculated with a spectrophotometer. A total of 100 resin cement specimens were prepared from Calibra Veneer, and the microhardness of the resin cement was measured with a Vickers microhardness device. RESULTS: In all CAD-CAM blocks, TP decreased as thickness increased (P < 0.05). Microhardness values for the top surface were lower than that of the control group for all groups except the LU 0.5 mm group (P < 0.05). Microhardness values for the bottom surface were lower than that of the control group in all groups (P < 0.05). In addition, microhardness was lower immediately after polymerization than at 24 h after polymerization in all groups (P < 0.05). CONCLUSION: The microhardness of a light-cured resin cement varied in relation to the material and thickness of the CAD-CAM block and was higher at 24 h after polymerization.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Innovative concrete reinforcement materials · Innovations in Concrete and Construction Materials · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Antalya Oral and Dental Health Hospital
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University
References (38)
Show source-provided references
1. 1. Spitznagel FA, Boldt J, Gierthmuehlen PC (2018) CAD/CAM ceramic restorative materials for natural teeth. J Dent Res 97, 1082-1091. doi: 10.1177/002203451877975910.1177/0022034518779759 ↗
2. 2. Barutçugil Ç, Bilgili D, Barutcigil K, Dündar A, Büyükkaplan UŞ, Yilmaz B (2019) Discoloration and translucency changes of CAD-CAM materials after exposure to beverages. J Prosthet Dent 122, 325-331. doi: 10.1016/j.prosdent.2019.01.00910.1016/j.prosdent.2019.01.009 ↗
3. 3. Bayindir F, Koseoglu M (2020) The effect of restoration thickness and resin cement shade on the color and translucency of a high-translucency monolithic zirconia. J Prosthet Dent 123, 149-154. doi: 10.1016/j.prosdent.2018.11.00210.1016/j.prosdent.2018.11.002 ↗
4. 4. Wang F, Takahashi H, Iwasaki N (2013) Translucency of dental ceramics with different thicknesses. J Prosthet Dent 110, 14-20. doi: 10.1016/s0022-3913(13)60333-910.1016/S0022-3913(13)60333-9 ↗
5. 5. Sulaiman TA, Abdulmajeed AA, Donovan TE, Ritter AV, Vallittu PK, Närhi TO et al. (2015) Optical properties and light irradiance of monolithic zirconia at variable thicknesses. Dent Mater 31, 1180-1187. doi: 10.1016/j.dental.2015.06.01610.1016/j.dental.2015.06.016 ↗
6. 6. Faria-e-Silva A, Boaro L, Braga R, Piva E, Arias V, Martins L (2011) Effect of immediate or delayed light activation on curing kinetics and shrinkage stress of dual-cure resin cements. Oper Dent 36, 196-204. doi: 10.2341/10-153-l10.2341/10-153-L ↗
7. 7. Malkondu O, Tinastepe N, Kazazoglu E (2016) Influence of type of cement on the color and translucency of monolithic zirconia. J Prosthet Dent 116, 902-908. doi: 10.1016/j.prosdent.2016.05.00110.1016/j.prosdent.2016.05.001 ↗
8. 8. Svizero Nda R, Silva MS, Alonso RC, Rodrigues FP, Hipólito VD, Carvalho RM et al. (2013) Effects of curing protocols on fluid kinetics and hardness of resin cements. Dent Mater J 32, 32-41. doi: 10.4012/dmj.2012-08510.4012/dmj.2012-085 ↗
9. 9. Fidalgo-Pereira R, Torres O, Carvalho Ó, Silva FS, Catarino SO, Özcan M et al. (2023) A scoping review on the polymerization of resin-matrix cements used in restorative dentistry. Materials (Basel) 16, 1560. doi: 10.3390/ma1604156010.3390/ma16041560 ↗
10. 10. De Souza G, Braga RR, Cesar PF, Lopes GC (2015) Correlation between clinical performance and degree of conversion of resin cements: a literature review. J Appl Oral Sci 23, 358-368. doi: 10.1590/1678-77572014052410.1590/1678-775720140524 ↗
11. 11. Yan YL, Kim YK, Kim KH, Kwon TY (2010) Changes in degree of conversion and microhardness of dental resin cements. Oper Dent 35, 203-210. doi: 10.2341/09-174-l10.2341/09-174-L ↗
12. 12. Moore BK, Platt JA, Borges G, Chu TM, Katsilieri I (2008) Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades. Oper Dent 33, 408-412. doi: 10.2341/07-10410.2341/07-104 ↗
13. 13. Jakupovic S, Pervan N, Mesic E, Gavranovic-Glamoc A, Bajsman A, Muratovic E, Kazazić L et al. (2023) Assessment of microhardness of conventional and bulk-fill resin composites using different light-curing intensity. Polymers (Basel) 15, 2250. doi: 10.3390/polym1510225010.3390/polym15102250 ↗
14. 14. Jung H, Friedl KH, Hiller KA, Furch H, Bernhart S, Schmalz G (2006) Polymerization efficiency of different photocuring units through ceramic discs. Oper Dent 31, 68-77. doi: 10.2341/04-18810.2341/04-188 ↗
15. 15. Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A (2012) Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials? Dent Mater 28, 521-528. doi: 10.1016/j.dental.2012.02.00210.1016/j.dental.2012.02.002 ↗
16. 16. Fasham T, Attal JP, Gouze H, Abdel-Gawad S, Dursun E, François P (2024) Effects of CAD/CAM restorative materials and thickness on the depth of cure of various light-cured resin composite materials. Dent Mater J 43, 822-834. doi: 10.4012/dmj.2024-05310.4012/dmj.2024-053 ↗
17. 17. Bouschlicher MR, Rueggeberg FA, Wilson BM (2004) Correlation of bottom-to-top surface microhardness and conversion ratios for a variety of resin composite compositions. Oper Dent 29, 698-704.
18. 18. Kesrak P, Leevailoj C (2012) surface hardness of resin cement polymerized under different ceramic materials. Int J Dent 2012, 317-509. doi: 10.1155/2012/31750910.1155/2012/317509 ↗
19. 19. Batmaz SG, Dündar A, Barutçugil Ç (2023) The effect of layer thickness and light intensity on the degree of conversion, microhardness and cytotoxicity of bulk fill composite resins. Clin Exp Health Sci 13, 795-801. doi: 10.33808/clinexphealthsci.118755710.33808/clinexphealthsci.1187557 ↗
20. 20. Stawarczyk B, Liebermann A, Eichberger M, Güth JF (2016) Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites. J Mech Behav Biomed Mater 55, 1-11. doi: 10.1016/j.jmbbm.2015.10.00410.1016/j.jmbbm.2015.10.004 ↗
21. 21. Stawarczyk B, Awad D, Ilie N (2016) Blue-light transmittance of esthetic monolithic cad/cam materials with respect to their composition, thickness, and curing conditions. Oper Dent 41, 531-540. doi: 10.2341/15-252-l10.2341/15-252-L ↗
22. 22. Ilie N, Hickel R (2008) Correlation between ceramics translucency and polymerization efficiency through ceramics. Dent Mater 24, 908-914. doi: 10.1016/j.dental.2007.11.00610.1016/j.dental.2007.11.006 ↗
23. 23. AlShaafi MM, AlQahtani MQ, Price RB (2014) Effect of exposure time on the polymerization of resin cement through ceramic. J Adhes Dent 16, 129-135. doi: 10.3290/j.jad.a30756
24. 24. Jafari Z, Alaghehmand H, Samani Y, Mahdian M, Khafri S (2018) Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement. Restor Dent Endod 43, 27. doi: 10.5395/rde.2018.43.e2710.5395/rde.2018.43.e27 ↗
25. 25. Höland W, Schweiger M, Frank M, Rheinberger V (2000) A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics. J Biomed Mater Res 53, 297-303. doi: 10.1002/1097-4636(2000)53:4%3C297::aid-jbm3%3E3.0.co;2-g10.1002/1097-4636(2000)53:4<297::AID-JBM3>3.0.CO;2-G ↗
26. 26. Donmez MB, Yucel MT (2019) Effect of monolithic CAD-CAM ceramic thickness on resin cement polymerization: an in-vitro study. Am J Dent 32, 240-244.
27. 27. Okutan Y, Kandemir B, Donmez MB, Yucel MT (2022) Effect of the thickness of CAD-CAM materials on the shear bond strength of light-polymerized resin cement. Eur J Oral Sci 130, 128-192. doi: 10.1111/eos.1289210.1111/eos.12892 ↗
28. 28. Canatan S, Oz FD, Bolay S (2022) A randomized, controlled clinical evaluation of two resin cement systems in the adhesion of cad/cam-fabricated resin nanoceramic restorations: 18-month preliminary results. J Esthet Restor Dent 34, 1005-1014. doi: 10.1111/jerd.1291010.1111/jerd.12910 ↗
29. 29. Scholz KJ, Tabenski IM, Vogl V, Cieplik F, Schmalz G, Buchalla W et al. (2021) Randomized clinical split-mouth study on the performance of cad/cam-partial ceramic crowns luted with a self-adhesive resin cement or a universal adhesive and a conventional resin cement after 39 months. J Dent 115, 103837 doi: 103837. 10.1016/j.jdent.2021.10383710.1016/j.jdent.2021.103837 ↗
30. 30. Ikemoto S, Komagata Y, Yoshii S, Masaki C, Hosokawa R, Ikeda H (2024) Impact of cad/cam material thickness and translucency on the polymerization of dual-cure resin cement in endocrowns. Polymers (Basel) 16, 661. doi:10.3390/polym1605066110.3390/polym16050661 ↗
31. 31. Turp V, Ongul D, Gultekin P, Bultan O, Karataslı B, Pak Tunc E (2015) Polymerization efficiency of two dual-cure cements through dental ceramics. J Istanb Univ Fac Dent 49, 10-18. doi: 10.17096/jiufd.2557510.17096/jiufd.25575 ↗
32. 32. Alvarenga M, Machado L, Prado A, Veloso S, Monteiro G (2024) Self-adhesive resin cement versus conventional cements on the failure rate of indirect single-tooth restorations: a systematic review and meta-analysis of randomized clinical trials. J Prosthet Dent 132, 880.e1-880.e8. doi: 10.1016/j.prosdent.2024.04.02710.1016/j.prosdent.2024.04.027 ↗
33. 33. Öztürk E, Bolay Ş, Hickel R, Ilie N (2013) Shear bond strength of porcelain laminate veneers to enamel, dentine and enamel-dentine complex bonded with different adhesive luting systems. J Dent 41, 97-105. doi: 10.1016/j.jdent.2012.04.00510.1016/j.jdent.2012.04.005 ↗
34. 34. Barutcigil K, Büyükkaplan UŞ (2020) The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements. J Adv Prosthodont 12, 61-66. doi: 10.4047/jap.2020.12.2.6110.4047/jap.2020.12.2.61 ↗
35. 35. Runnacles P, Correr GM, Baratto Filho F, Gonzaga CC, Furuse AY (2014) Degree of conversion of a resin cement light-cured through ceramic veneers of different thicknesses and types. Braz Dent J 25, 38-42. doi: 10.1590/0103-644020130220010.1590/0103-6440201302200 ↗
36. 36. Ilie N, Furtos G (2020) A comparative study of light transmission by various dental restorative materials and the tooth structure. Oper Dent 45, 442-452. doi: 10.2341/19-037-l10.2341/19-037-L ↗
37. 37. Ilie N (2017) Transmitted irradiance through ceramics: effect on the mechanical properties of a luting resin cement. Clin Oral Investig 21, 1183-1190. doi: 10.1007/s00784-016-1891-310.1007/s00784-016-1891-3 ↗
38. 38. Borges GA, Agarwal P, Miranzi BA, Platt JA, Valentino TA, dos Santos PH (2008) Influence of different ceramics on resin cement knoop hardness number. Oper Dent 33, 622-628. doi: 10.2341/07-15510.2341/07-155 ↗