Quantitative evaluation of axial wall taper in prepared artificial teeth
Source abstract
Abstract
The purpose of this study was to quantitatively evaluate the axial wall taper of prepared artificial teeth using a non-contact three-dimensional shape measuring system. A total of 54 artificial teeth prepared by pre-clinical dental students for complete cast restorations were evaluated. For quantitative analysis, five cross sections were computer-graphically placed perpendicularly to the z-axis. The surface coordinate values (x, y, z) of each cross section were converted into polar coordinate values (r, theta), which were then graphically rendered to a two-dimensional plane. At four points, each 90 degrees from the distal center point of the cross section, the axial wall taper was quantitatively calculated using a formula based on the differences in radius between the highest and lowest positions of the cross sections of the prepared tooth. The average calculated taper was 5.8 degrees in the distal region, 21.7 degrees in the buccal region, 14.9 degrees in the mesial region and 12.5 degrees in the lingual region. These results suggest that the axial wall taper of prepared teeth can be quantitatively evaluated using this measuring system.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. 1. Rekow D (1987) Computer-aided design and manufacturing in dentistry: a review of the state of the art. J Prosthet Dent 58, 512-51610.1016/0022-3913(87)90285-X ↗
2. 2. Mörmann WH, Bindl A (1996) The new creativity in ceramic restorations: dental CAD-CIM. Quintessence Int 27, 821-828
3. 3. Mou SH, Chai T, Wang JS, Shiau YY (2002) Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns. J Prosthet Dent 87, 248-25510.1067/mpr.2002.122011 ↗
4. 4. Nakamura T, Dei N, Kojima T, Wakabayashi K (2003) Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns. Int J Prosthodont 16, 244-248
5. 5. Bindl A, Mörmann WH (2005) Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 32, 441-44710.1111/j.1365-2842.2005.01446.x ↗
6. KIMURA H · 1990 · 30 · 31
7. 7. Sohmura T, Takahashi J (1995) Use of CAD/CAM system to fabricate dental prostheses. Part 1: CAD for a clinical crown restoration. Int J Prosthodont 8, 252-258
8. 8. Ohm E, Silness J (1978) The convergence angle in teeth prepared for artificial crowns. J Oral Rehabil 5, 371-37510.1111/j.1365-2842.1978.tb01256.x ↗
9. 9. Nordlander J, Weir D, Stoffer W, Ochi S (1988) The taper of clinical preparations for fixed prosthodontics. J Prosthet Dent 60, 148-15110.1016/0022-3913(88)90304-6 ↗
10. SATO T · 1998 · 45 · 205
11. 11. Kournetas N, Jaeger B, Axmann D, Groten M, Lachmann S, Weber H, Geis-Gerstorfer J (2004) Assessing the reliability of a digital preparation assistant system used in dental education. J Dent Educ 68, 1228-123410.1002/j.0022-0337.2004.68.12.tb03872.x ↗
12. 12. Buchanan JA (2004) Experience with virtual reality-based technology in teaching restorative dental procedures. J Dent Educ 68, 1258-126510.1002/j.0022-0337.2004.68.12.tb03875.x ↗